Qualitative and quantitative analysis of 3D T1 Silent imaging
- PMID: 34131844
- DOI: 10.1007/s11547-021-01380-6
Qualitative and quantitative analysis of 3D T1 Silent imaging
Abstract
Purpose: To compare brain magnetic resonance imaging (MRI) using T1 3D Silent and fast T1 3D Gradient-Echo (GRE) BRAin VOlume (known as BRAVO) sequences. The primary aim is to assess the quantitative and qualitative analysis of Silent and BRAVO images by the measurement of the contrast (C), the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR). The second aim is to estimate the subjective sound levels and the specific absorption rate (SAR).
Methods: Twenty-two subjects had T1 3D Silent and T1 3D BRAVO sequences added to the standard MR examination. The qualitative analysis of the two sequences was performed by two radiologists independently. The quantitative analysis was performed by placing regions of interest on the cerebrospinal fluid, on the white and grey matter. The C, the CNR and the SNR were calculated for each sequence. After each T1-3D sequence, subjects gave a score rating to evaluate the acoustic noise. Finally, the SAR was evaluated by the digital imaging and communications in medicine (DICOM) tags.
Results: The image quality scores obtained by the two radiologists were higher for BRAVO compared to the Silent. However, qualitatively, the Silent images were similar to BRAVO for diagnostic use. Quantitatively, CNR for GM-CSF was comparable in the two sequences and SNR in CSF was higher in Silent than BRAVO. The acoustic noise of Silent sequence was statistically lower compared with BRAVO. The maximum SAR measured was 1.4 W/kg.
Conclusions: 3D T1 Silent can be a valid alternative technique to conventional BRAVO to reduce the acoustic noise preserving the diagnostic accuracy. However, radiologists preferred the conventional sequence to Silent.
Keywords: Acoustic noise; Magnetic resonance imaging; Neuroimaging; Silent scan; Zero time of echo.
© 2021. Italian Society of Medical Radiology.
Similar articles
-
Assessment of Silent T1-weighted head imaging at 7 T.Eur Radiol. 2016 Jun;26(6):1879-88. doi: 10.1007/s00330-015-3954-2. Epub 2015 Aug 29. Eur Radiol. 2016. PMID: 26318369
-
Comparison of Routine Brain Imaging at 3 T and 7 T.Invest Radiol. 2016 Aug;51(8):469-82. doi: 10.1097/RLI.0000000000000256. Invest Radiol. 2016. PMID: 26863580 Free PMC article.
-
Compressed Sensing-Sensitivity Encoding (CS-SENSE) Accelerated Brain Imaging: Reduced Scan Time without Reduced Image Quality.AJNR Am J Neuroradiol. 2019 Jan;40(1):92-98. doi: 10.3174/ajnr.A5905. Epub 2018 Dec 6. AJNR Am J Neuroradiol. 2019. PMID: 30523142 Free PMC article.
-
Silent zero TE MR neuroimaging: Current state-of-the-art and future directions.Prog Nucl Magn Reson Spectrosc. 2021 Apr;123:73-93. doi: 10.1016/j.pnmrs.2021.03.002. Epub 2021 Mar 26. Prog Nucl Magn Reson Spectrosc. 2021. PMID: 34078538 Free PMC article. Review.
-
Acoustic Noise and Magnetic Resonance Imaging: A Narrative/Descriptive Review.J Magn Reson Imaging. 2022 Feb;55(2):337-346. doi: 10.1002/jmri.27525. Epub 2021 Feb 25. J Magn Reson Imaging. 2022. PMID: 33629790 Review.
Cited by
-
Hypersensitive MR angiography based on interlocking stratagem for diagnosis of cardiac-cerebral vascular diseases.Nat Commun. 2023 Oct 2;14(1):6149. doi: 10.1038/s41467-023-41783-9. Nat Commun. 2023. PMID: 37783733 Free PMC article.
-
Radiological assessment of dementia: the Italian inter-society consensus for a practical and clinically oriented guide to image acquisition, evaluation, and reporting.Radiol Med. 2022 Sep;127(9):998-1022. doi: 10.1007/s11547-022-01534-0. Epub 2022 Sep 7. Radiol Med. 2022. PMID: 36070064 Free PMC article.
-
Compressed SENSitivity Encoding (SENSE): Qualitative and Quantitative Analysis.Diagnostics (Basel). 2024 Aug 5;14(15):1693. doi: 10.3390/diagnostics14151693. Diagnostics (Basel). 2024. PMID: 39125569 Free PMC article.
-
Diffusion weighted imaging and diffusion kurtosis imaging in abdominal oncological setting: why and when.Infect Agent Cancer. 2022 Jun 9;17(1):25. doi: 10.1186/s13027-022-00441-3. Infect Agent Cancer. 2022. PMID: 35681237 Free PMC article. Review.
-
Peritoneal Carcinosis: What the Radiologist Needs to Know.Diagnostics (Basel). 2023 Jun 5;13(11):1974. doi: 10.3390/diagnostics13111974. Diagnostics (Basel). 2023. PMID: 37296826 Free PMC article. Review.
References
-
- Picchi E, Di Giuliano F, Marziali S et al (2019) Radiological findings of posterior reversible encephalopathy syndrome in transplanted children previous affected by hemoglobinopathy: a neuroimaging retrospective analysis. Eur J Radiol Open. https://doi.org/10.1016/j.ejro.2019.03.001 - DOI - PubMed - PMC
-
- Minosse S, Garaci F, Martucci A et al (2019) Primary open angle glaucoma is associated with functional brain network reorganization. Front Neurol. https://doi.org/10.3389/fneur.2019.01134 - DOI - PubMed - PMC
-
- Minosse S, Vidiri A, Piludu F, Marzi S (2016) Diffusion kurtosis imaging in head and neck and brain tumor: a feasibility study. Physica Medica 32:130–131 - DOI
-
- Garaci F, Picchi E, Di Giuliano F et al (2019) Cerebral multishell diffusion imaging parameters are associated with blood biomarkers of disease severity in HIV infection. J Neuroimaging. https://doi.org/10.1111/jon.12655 - DOI - PubMed
-
- Holdsworth SJ, MacPherson SJ, Yeom KW et al (2018) Clinical evaluation of silent T1-weighted MRI and silent MR angiography of the brain. Am J Roentgenol. https://doi.org/10.2214/AJR.17.18247 - DOI
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous