Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Jun 16;11(1):12647.
doi: 10.1038/s41598-021-92233-9.

A 2-year prospective multicenter study of ultrasound cyclo plasty for glaucoma

Affiliations

A 2-year prospective multicenter study of ultrasound cyclo plasty for glaucoma

Giuseppe Giannaccare et al. Sci Rep. .

Abstract

Ultrasound cyclo plasty (UCP) is a recently developed surgical technique for glaucoma allowing a selective and controlled coagulation of the ciliary body. We herein investigated the long-term efficacy and safety of UCP for the treatment of glaucoma. This prospective study included patients with primary and secondary glaucoma. All surgeries were performed using the EyeOP1 device (Eye Tech Care, Rillieux-la-Pape, France). Sixty-six patients were included, and 60 completed regularly the 2-year follow-up. Preoperative IOP was 28.5 ± 9.6 mmHg and significantly decreased to 17.0 ± 5.4 at 2 years (p < 0.001). The daily number of both hypotensive eye drops and acetazolamide tablets decreased significantly (respectively, from 2.6 ± 1.1 to 1.7 ± 1.2 and from 0.7 ± 0.8 to 0.2 ± 0.5; both p < 0.001). At 2 years, 68.1% of patients met the definition of qualified success (IOP < 21 mmHg regardless of glaucoma medications) and 10.3% of patients met the definition of complete success (IOP < 21 mmHg without glaucoma medications). No major intra- or postoperative complications occurred; however, 15 eyes required additional glaucoma surgery. These results suggest that UCP is an effective and safe procedure to reduce IOP in glaucoma patients through a 2-year follow-up period.

PubMed Disclaimer

Conflict of interest statement

The authors declare no competing interests.

Figures

Figure 1
Figure 1
Intraocular pressure values throughout the 2-year follow-up period. The figure was created using R (version 4.0.0) and RStudio (version 1.2.5042) software (https://www.rstudio.com).
Figure 2
Figure 2
Kaplan–Meier survival curves of qualified success (A) and complete success (B) after ultrasound cyclo plasty. The figure was created using R (version 4.0.0) and RStudio (version 1.2.5042) software (https://www.rstudio.com).

References

    1. Quigley HA, Broman AT. The number of people with glaucoma worldwide in 2010 and 2020. Br. J. Ophthalmol. 2006;90:262–267. doi: 10.1136/bjo.2005.081224. - DOI - PMC - PubMed
    1. Floriani I, et al. Health-related quality of life in patients with primary open-angle glaucoma. An Italian multicentre observational study. Acta Ophthalmol. 2016;94:e278–e286. doi: 10.1111/aos.12890. - DOI - PubMed
    1. Rulli E, et al. Visual field loss and vision-related quality of life in the Italian Primary Open Angle Glaucoma Study. Sci. Rep. 2018;8:619. doi: 10.1038/s41598-017-19113-z. - DOI - PMC - PubMed
    1. Riva I, et al. Influence of sociodemographic factors on disease characteristics and vision-related quality of life in primary open-angle glaucoma patients: The Italian Primary Open Angle Glaucoma Study (IPOAGS) J. Glaucoma. 2018;27:776–784. doi: 10.1097/IJG.0000000000000989. - DOI - PubMed
    1. Shen J, Wang Y, Yao K. Protection of retinal ganglion cells in glaucoma: Current status and future. Exp. Eye. Res. 2021;205:108506. doi: 10.1016/j.exer.2021.108506. - DOI - PubMed