Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Jun 1:25:42-46.
doi: 10.1016/j.asmart.2021.05.007. eCollection 2021 Jul.

Randomized comparative study of suspension femoral fixation device in graft position maintenance in anterior cruciate ligament reconstruction: EndoButton CL vs TightRope RT

Affiliations

Randomized comparative study of suspension femoral fixation device in graft position maintenance in anterior cruciate ligament reconstruction: EndoButton CL vs TightRope RT

Yoshimasa Ono et al. Asia Pac J Sports Med Arthrosc Rehabil Technol. .

Abstract

Background: In double-bundle anterior cruciate ligament reconstruction (ACLR), fixed-loop and adjustable-loop cortical suspensory devices are commonly used to fix the soft graft on the femoral side. However, few studies have compared in vivo elongation of the two devices. The purpose of this study was to determine whether EndoButton CL (EB) and TightRope RT (TR), the suspensory fixation devices used in ACLR, maintained their length in vivo from the time of surgery through the postoperative period in a randomized controlled trial.

Methods: This study prospectively incorporated 30 patients undergoing initial ACLR at a single center. Participants were divided into two groups using a stratified randomization method with age and sex as assignment adjustment factors. EB or TR was used for fixation of the soft graft on the femoral side. The primary endpoint was to compare the elongation distance of the suspensory device. MRIs were taken within seven days after ACLR and 3,6,12 months postoperatively and measured by a radiologist in a blinded fashion. Secondary endpoints included the side-to-side difference in anterior translation, one leg hop test (HOP index), Lachman test, lateral pivot shift test, and Lysholm score one year postoperatively.

Results: Twenty-eight patients (EB, n = 13; TR, n = 15) were followed for one year. There was no significant difference between EB and TR groups in elongation from the immediate postoperative period to 3, 6, 12 months after surgery. However, the non-inferiority of TR to EB (non-inferiority margin: 1.5 mm) was not proved by the difference in measured elongation between the two groups (TR - EB, lower 95% CI. AM: 1.80 mm; PL: 1.86 mm) at 6 months. There was no significant difference in anterior translation, HOP index, Lachman test, lateral pivot shift test, or Lysholm score.

Conclusion: EB and TR had similar graft retaining ability in vivo for 12 months, but the non-inferiority of TR against EB was not verified statistically.

Keywords: Adjustable loop; Anterior cruciate ligament reconstruction; Cortical suspensory fixation device; Fixed loop.

PubMed Disclaimer

Conflict of interest statement

This study was financially supported by Arthrex Japan LLC as an investigator initiated research grant (ID: APAC6).

Figures

Fig. 1
Fig. 1
Schematic and MRI measurements of the distance from the reconstructed ligament to the lateral cortical bone of the femur. Red line: Distance between the lateral cortical surface of the femur and the tip of graft; Blue line: Axis of the femoral tunnel; Yellow line: Axis perpendicular to femoral tunnel axis. (For interpretation of the references to colour in this figure legend, the reader is referred to the Web version of this article.)
Fig. 2
Fig. 2
CONSORT flow diagram. EB, EndoButton; TR, TightRope. (This figure is uploaded separately.)

References

    1. Ahn J.H., Ko T.S., Lee Y.S., Jeong H.J., Park J.K. Magnetic resonance imaging and clinical results of outside-in anterior cruciate ligament reconstruction: a comparison of fixed-and adjustable-length loop cortical fixation. Clin Orthop Surg. 2018;10:157–166. - PMC - PubMed
    1. Barrow A.E., Pilia M., Guda T., Kadrmas W.R., Burns T.C. Femoral suspension devices for anterior cruciate ligament reconstruction: do adjustable loops lengthen? Am J Sports Med. 2014;42:343–349. - PubMed
    1. Chang M.J., Bae T.S., Moon Y.W., Ahn J.H., Wang J.H. A comparative biomechanical study of femoral cortical suspension devices for soft-tissue anterior cruciate ligament reconstruction: adjustable-length loop versus fixed-length loop. Arthroscopy. 2018;34:566–572. - PubMed
    1. Daniel D., Stone M., Riehl B. A measurement of lower limb function: the one leg hop distance. Am J Knee Surg. 1988;1:212–214.
    1. Eguchi A., Ochi M., Adachi N., Deie M., Nakamae A., Usman M.A. Mechanical properties of suspensory fixation devices for anterior cruciate ligament reconstruction: comparison of the fixed-length loop device versus the adjustable-length loop device. Knee. 2014;21:743–748. - PubMed

LinkOut - more resources