Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Jun 21;11(1):12971.
doi: 10.1038/s41598-021-92396-5.

Contrast sensitivity and higher-order aberrations in Keratoconus subjects

Affiliations

Contrast sensitivity and higher-order aberrations in Keratoconus subjects

Einat Shneor et al. Sci Rep. .

Abstract

This study analyzes the relationship between contrast-sensitivity and higher-order aberrations (HOA) in mild and subclinical-keratoconus in subjects with good visual-acuity (VA). Keratoconus group (including subclinical-keratoconus) and controls underwent autokeratometry, corneal-tomography, autorefraction and HOA measurement. Contrast-sensitivity was tested using a psychophysical two-alternative forced-choice Gabor patches in three blocks (6, 9, 12 cycles/deg). Controls were compared to the keratoconus group and to a keratoconus subgroup with VA of 0.00 LogMar group ("keratoconus-0.00VA"). Spearman correlation tested association between HOA and contrast-sensitivity. Twenty-two keratoconus subjects (38 eyes: 28 keratoconus, 10 subclinical-keratoconus, 20 keratoconus-0.00VA) and 35 controls were included. There was a significant difference between control and keratoconus, and between control and keratoconus-0.00VA, for keratometry, cylinder, thinnest and central corneal thickness (p < 0.001). Controls showed lower HOA and higher contrast-sensitivity for all spatial-frequencies (p < 0.001). Most HOA were negatively correlated with contrast-sensitivity for all spatial-frequencies for keratoconus group and for 9 and 12 cycles/deg for keratoconus-0.00VA. Keratoconus subjects with good VA showed reduction in contrast-sensitivity and increased HOAs compared to controls. HOA and contrast-sensitivity are inversely correlated in subjects with mild keratoconus despite good VA. This suggests that the main mechanism underlying the decreased vision quality in keratoconus is the increase of HOA.

PubMed Disclaimer

Conflict of interest statement

The authors declare no competing interests.

Figures

Figure 1
Figure 1
Contrast Sensitivity in different frequencies for keratoconus group, keratoconus subjects with visual acuity of 0.00 LogMar and for control group. Blue bars represent contrast sensitivity for keratoconus subjects, orange bars represent contrast sensitivity for keratoconus subjects with visual acuity of 0.00 LogMar and gray bars represent contrast sensitivity for Control subjects. *Significant level of < 0.005. The figure was generated using Microsoft 365 Excel Version 2103 and the resolution adjusted using Microsoft 365 PowerPoint Version 2103.

References

    1. Gordon-Shaag A, Millodot M, Shneor E, Liu Y. The genetic and environmental factors for keratoconus. Biomed. Res. Int. 2015;2015:795738. doi: 10.1155/2015/795738. - DOI - PMC - PubMed
    1. Rabinowitz YS. The genetic and environmental factors for keratoconus. Surv. Ophthalmol. 1998;42(4):297–319. doi: 10.1016/S0039-6257(97)00119-7. - DOI - PubMed
    1. Alió JL, Shabayek MH. Corneal higher order aberrations: a method to grade keratoconus. J. Refract. Surg. 2006;22(6):539–545. doi: 10.3928/1081-597X-20060601-05. - DOI - PubMed
    1. Gomes JA, Rapuano CJ, Belin MW, Ambrósio R., Jr Global consensus on keratoconus diagnosis. Cornea. 2015;34(12):e38–e39. doi: 10.1097/ICO.0000000000000623. - DOI - PubMed
    1. Kandel H, Pesudovs K, Watson SL. Measurement of quality of life in keratoconus. Cornea. 2020;39(3):386–393. doi: 10.1097/ICO.0000000000002170. - DOI - PubMed