Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Dec;25(12):3160-3169.
doi: 10.1007/s11605-021-04925-2. Epub 2021 Jun 22.

Intraoperative (Contrast-Enhanced) Ultrasound Has the Highest Diagnostic Accuracy of Any Imaging Modality in Resection of Colorectal Liver Metastases

Affiliations

Intraoperative (Contrast-Enhanced) Ultrasound Has the Highest Diagnostic Accuracy of Any Imaging Modality in Resection of Colorectal Liver Metastases

Gregor A Stavrou et al. J Gastrointest Surg. 2021 Dec.

Abstract

Aim: Defining sensitivity, specificity, diagnostic accuracy for detection of colorectal liver metastases in imaging compared to intraoperative assessment. Defining a cutoff, where accuracy of detection is impaired.

Methods: Prospective single-institution clinical trial (clinicaltrials.gov: NCT01522209). Patients underwent CEUS, MDCT, and 3 Tesla EOB-MRI within 2 weeks preoperatively. Intraoperative palpation, IOUS, and CEIOUS were performed. A patient and lesion-based database was analyzed for accuracy of detection of CEUS, CT, MRI, and Palp/IOUS/CEIOUS combined read. Histology was standard of reference.

Results: Forty-seven high tumor load (mean 5, 4 lesions) patients were analyzed. Histopathology confirmed 264 lesions (245 malignant: 19 benign). Accuracy for detection of all lesions: CEUS 63%, CT 71%, MRI 92%, and PALP/IOUS/CEIOUS 98%. ROC analysis for lesion size showed severe impairment of accuracy in lesion detection smaller than 5mm. Intraoperative imaging was not impaired by lesion size. Patient-based analysis revealed a change of resection plan after IOUS/CEIOUS in 35% of patients.

Conclusion: At 5-mm lesion size, preoperative imaging shows a drop in accuracy of detection. In patients with multiple lesions, addition of MRI to MDCT seems useful. Accuracy of intraoperative ultrasound is not impacted by lesion size and should be mandatory. CEIOUS can improve intraoperative decision-making.

Trial registration: Study registered with clinicaltrials.gov : NCT01522209.

Keywords: Accuracy; CEIOUS; Colorectal; IOUS; Imaging; Liver metastasis; Sensitivity; Specificity.

PubMed Disclaimer

References

    1. Mullen JT, Ribero D, Reddy SK, Donadon M, Zorzi D, Gautam S, et al. Hepatic insufficiency and mortality in 1,059 noncirrhotic patients undergoing major hepatectomy. ACS. 2007 May;204(5):854–62–discussion862–4.
    1. van Cutsem E, Nordlinger B, Adam R, Köhne C-H, Pozzo C, Poston G, et al. Towards a pan-European consensus on the treatment of patients with colorectal liver metastases. Eur J Cancer. Elsevier; 2006 Sep;42(14):2212–21.
    1. Folprecht G, Gruenberger T, Bechstein WO, Raab H-R, Lordick F, Hartmann JT, et al. Tumour response and secondary resectability of colorectal liver metastases following neoadjuvant chemotherapy with cetuximab: the CELIM randomised phase 2 trial. Lancet Oncol. 2010 Jan;11(1):38–47. - DOI
    1. Loupakis F, Stein A, Ychou M, Hermann F, Salud A, Österlund P. A Review of Clinical Studies and Practical Guide for the Administration of Triplet Chemotherapy Regimens with Bevacizumab in First-line Metastatic Colorectal Cancer. Target Oncol. Springer International Publishing; 2015 Dec 19;:1–16.
    1. Hurwitz H, Fehrenbacher L, Novotny W, Cartwright T, Hainsworth J, Heim W, et al. Bevacizumab plus irinotecan, fluorouracil, and leucovorin for metastatic colorectal cancer. N Engl J Med. 2004 Jun 3;350(23):2335–42. - DOI

Publication types

Associated data