Effectiveness of uterine tamponade devices for refractory postpartum haemorrhage after vaginal birth: a systematic review
- PMID: 34165867
- PMCID: PMC9292664
- DOI: 10.1111/1471-0528.16819
Effectiveness of uterine tamponade devices for refractory postpartum haemorrhage after vaginal birth: a systematic review
Abstract
Objectives: To evaluate uterine tamponade devices' effectiveness for atonic refractory postpartum haemorrhage (PPH) after vaginal birth and the effect of including them in institutional protocols.
Search strategy: PubMed, EMBASE, CINAHL, LILACS, POPLINE, from inception to January 2021.
Study selection: Randomised and non-randomised comparative studies.
Outcomes: Composite outcome including surgical interventions (artery ligations, compressive sutures or hysterectomy) or maternal death, and hysterectomy.
Results: All included studies were at high risk of bias. The certainty of the evidence was rated as very low to low. One randomised study measured the effect of the condom-catheter balloon compared with standard care and found unclear results for the composite outcome (relative risk [RR] 2.33, 95% CI 0.76-7.14) and hysterectomy (RR 4.14, 95% CI 0.48-35.93). Three comparative studies assessed the effect of including uterine balloon tamponade in institutional protocols. A stepped wedge cluster randomised controlled trial suggested an increase in the composite outcome (RR 4.08, 95% CI 1.07-15.58) and unclear results for hysterectomy (RR 4.38, 95% CI 0.47-41.09) with the use of the condom-catheter or surgical glove balloon. One non-randomised study showed unclear effects on the composite outcome (RR 0.33, 95% CI 0.11-1.03) and hysterectomy (RR 0.49, 95% CI 0.04-5.38) after the inclusion of the Bakri balloon. The second non-randomised study found unclear effects on the composite outcome (RR 0.95, 95% CI 0.32-2.81) and hysterectomy (RR 1.84, 95% CI 0.44-7.69) after the inclusion of Ebb or Bakri balloon.
Conclusions: The effect of uterine tamponade devices for the management of atonic refractory PPH after vaginal delivery is unclear, as is the role of the type of device and the setting.
Tweetable abstract: Unclear effects of uterine tamponade devices and their inclusion in institutional protocols for atonic refractory PPH after vaginal delivery.
Keywords: Bakri balloon; condom uterine balloon tamponade; hysterectomy; maternal death; postpartum haemorrhage; uterine atony; vaginal delivery.
© 2021 The Authors. BJOG: An International Journal of Obstetrics and Gynaecology published by John Wiley & Sons Ltd.
Figures
Comment in
-
What should we believe when systematic reviews disagree?BJOG. 2021 Oct;128(11):1744. doi: 10.1111/1471-0528.16818. Epub 2021 Jul 22. BJOG. 2021. PMID: 34165874 No abstract available.
References
-
- Say L, Chou D, Gemmill A, Tuncalp O, Moller AB, Daniels J, et al. Global causes of maternal death: a WHO systematic analysis. Lancet Glob Health 2014;2:e323–33. - PubMed
-
- World Health Organization . WHO Recommendations for the Prevention and Treatment of Postpartum Haemorrhage. Geneva, Switzerland: World Health Organization; 2012. - PubMed
-
- Widmer M, Piaggio G, Nguyen TMH, Osoti A, Owa OO, Misra S, et al. Heat‐stable carbetocin versus oxytocin to prevent hemorrhage after vaginal birth. N Engl J Med 2018;379:743–52. - PubMed
-
- Mousa HA, Cording V, Alfirevic Z. Risk factors and interventions associated with major primary postpartum hemorrhage unresponsive to first‐line conventional therapy. Acta Obstet Gynecol Scand 2008;87:652–61. - PubMed
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Medical