Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Aug;413(20):5147-5160.
doi: 10.1007/s00216-021-03481-7. Epub 2021 Jun 26.

Automated method to determine pharmaceutical compounds in wastewater using on-line solid-phase extraction coupled to LC-MS/MS

Affiliations

Automated method to determine pharmaceutical compounds in wastewater using on-line solid-phase extraction coupled to LC-MS/MS

César Augusto Marasco Júnior et al. Anal Bioanal Chem. 2021 Aug.

Abstract

An automated method was developed using on-line solid-phase extraction (SPE) as a sample preparation step, coupled to liquid chromatography-tandem mass spectrometry (LC-MS/MS), for determination of pharmaceutical compounds in wastewater samples at nanograms per liter to micrograms per liter concentration levels. This method is suitable for use in routine analysis, especially in environmental applications, avoiding cross-contamination and requiring minimal sample handling. Results can be obtained rapidly, with a chromatographic run time of only 24 min (including sample preparation and chromatographic analysis). Using a 50 μL injection volume, the method was validated according to international guidelines, considering parameters included in terms of method detection (MDL) and quantification limit (MQL), linearity, inter-day and intra-day precisions, and matrix effects. Assessment of chromatographic efficiency considered peak resolution and asymmetry, and carryover was evaluated to ensure analytical reliability and the ability to reuse the SPE cartridge. The intra- and inter-day precisions were lower than 10 and 17%, respectively. The MDL values ranged from 1×10-6 to 1 μg L-1, while the MQL values were from 0.001 to 3 μg L-1. Matrix effects were minimized by isotope dilution calibration. Application of the method to 20 wastewater samples showed that caffeine was the most frequently detected compound, with the highest concentration of 715 μg L-1, while other pharmaceutical compounds were detected in fewer samples and at lower concentrations (up to 8.51 μg L-1).

Keywords: Emerging contaminants; Liquid chromatography-tandem mass spectrometry; On-line sample preparation; Pharmaceutical compounds; Wastewater analysis.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Chinnaiyan P, Thampi SG, Kumar M, Mini KM. Pharmaceutical products as emerging contaminant in water: relevance for developing nations and identification of critical compounds for Indian environment. Environ Monit Assess. 2018;190:288. - PubMed - DOI
    1. Mohapatra DP, Kirpalani DM. Advancement in treatment of wastewater: fate of emerging contaminants. Can J Chem Eng. 2019;97:2621–31. - DOI
    1. Marasco Júnior CA, Luchiari NDC, Lima Gomes PCF. Occurrence of caffeine in wastewater and sewage and applied techniques for analysis: a review. Eclética Quím J. 2019;44:11–26. - DOI
    1. U.S. GAO Government Accountability Office Toxic Chemicals - High Risk Issue. https://www.gao.gov/key_issues/toxic_chemicals/issue_summary . Accessed on March 16, 2020.
    1. Mattarozzi M, Careri M. Liquid chromatography/mass spectrometry in environmental analysis. In: Meyers RA, editor. Encyclopedia of analytical chemistry. Chichester, UK: John Wiley & Sons, Ltd; 2015. p. 1–41.

MeSH terms

LinkOut - more resources