Dynamic visual acuity with telescopic spectacles: improvement with adaptation
- PMID: 3417408
Dynamic visual acuity with telescopic spectacles: improvement with adaptation
Abstract
Telescopic spectacles are used as aids for the visually impaired in order to increase effective visual acuity. Because ocular stabilization reflexes are not fully compensatory when telescopic spectacles are worn, head motion would be expected to produce retinal image motion which could decrease visual acuity. Using 1.0 Hz sinusoids of vertical axis head rotation, we investigated the effect of head velocity and telescopic spectacle magnification on binocular dynamic visual acuity (DVA), the acuity during head motion, in 34 normally sighted subjects. The visual field peripheral to the telescopes was masked. Up to a head velocity amplitude of 30 degrees/sec, DVA was insensitive to head velocity for X2 telescopic spectacles. For X4 and, to a greater degree, X6 telescopic spectacles, DVA decreased progressively as head velocity increased. DVA measurements were repeated after a 15 min adaptation period, during which a distant video monitor was viewed using telescopic spectacles. For X4 telescopic spectacles, DVA increased significantly after adaptation. With an unobstructed peripheral visual field, initial DVA with X4 telescopic spectacles was equal to adapted DVA with peripheral vision occluded, but adaptation produced no further improvement in DVA with the peripheral field unobstructed. These data indicate that the visual acuity obtained with telescopic spectacles is substantially reduced under conditions where head motion occurs, potentially reducing the functional value of these devices in low vision rehabilitation. The adverse effect of head motion on DVA may be reduced by adaptation.
Similar articles
-
Adaptation to telescopic spectacles: vestibulo-ocular reflex plasticity.Invest Ophthalmol Vis Sci. 1989 Jan;30(1):159-70. Invest Ophthalmol Vis Sci. 1989. PMID: 2912909
-
Dynamic visual acuity of normal subjects during vertical optotype and head motion.Invest Ophthalmol Vis Sci. 1993 May;34(6):1894-906. Invest Ophthalmol Vis Sci. 1993. PMID: 8491542
-
Visual-vestibular interaction with telescopic spectacles.J Vestib Res. 1990-1991;1(3):263-77. J Vestib Res. 1990. PMID: 1670159
-
Bioptic telescopic spectacles for motor vehicle driving.J Am Optom Assoc. 1991 Jan;62(1):37-41. J Am Optom Assoc. 1991. PMID: 1813491 Review.
-
[Use of a contact lens-eyeglass telescopic system in asthenopia].Vestn Oftalmol. 1986 May-Jun;102(3):73-4. Vestn Oftalmol. 1986. PMID: 3523942 Review. Russian. No abstract available.
Cited by
-
Preliminary Evaluation of Two Digital Image Processing Strategies for Head-Mounted Magnification for Low Vision Patients.Transl Vis Sci Technol. 2019 Feb 28;8(1):23. doi: 10.1167/tvst.8.1.23. eCollection 2019 Jan. Transl Vis Sci Technol. 2019. PMID: 30834171 Free PMC article.
-
Low Vision Enhancement with Head-mounted Video Display Systems: Are We There Yet?Optom Vis Sci. 2018 Sep;95(9):694-703. doi: 10.1097/OPX.0000000000001278. Optom Vis Sci. 2018. PMID: 30153240 Free PMC article.
-
Comparative effectiveness between two types of head-mounted magnification modes using a smartphone-based virtual display.Optom Vis Sci. 2024 Jun 1;101(6):342-350. doi: 10.1097/OPX.0000000000002115. Epub 2024 Apr 12. Optom Vis Sci. 2024. PMID: 38551973 Free PMC article. Clinical Trial.
-
Perceptual Adaptation to Continuous Versus Intermittent Exposure to Spatial Distortions.Invest Ophthalmol Vis Sci. 2022 May 2;63(5):29. doi: 10.1167/iovs.63.5.29. Invest Ophthalmol Vis Sci. 2022. PMID: 35612838 Free PMC article.
-
The contribution of image minification to discomfort experienced in wearable optics.J Vis. 2023 Aug 1;23(8):10. doi: 10.1167/jov.23.8.10. J Vis. 2023. PMID: 37552022 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Medical