Meta-Analysis
. 2022 Jul;38(3):309-314.
doi: 10.1007/s11282-021-00549-z. Epub 2021 Jun 26.

Evaluation of the accuracy values of cone-beam CT regarding apical periodontitis: a systematic review and meta-analysis

Affiliations
Meta-Analysis

Evaluation of the accuracy values of cone-beam CT regarding apical periodontitis: a systematic review and meta-analysis

Marjan Mostafapoor et al. Oral Radiol. 2022 Jul.

Abstract

Specialists need to know how accurate and effective each radiographic procedure is, and which ones can provide better images for bone resorption around the apical periodontitis. Therefore, the researcher decided to conduct the present study with the aim of evaluate the accuracy values of cone-beam CT regarding apical periodontitis. The PubMed, Embase, ISI, Scopus, and Medicine have been used to search articles over the last 15 years between 2005 and December 2020. Meta-analysis data with 95% confidence interval (CI), Random effect model, and restricted maximum-likelihood methods were calculated. Random effects were used to deal with potential heterogeneity and I2 showed heterogeneity. I2 values above 50% signified moderate-to-high heterogeneity. The meta-analysis has been evaluated with the statistical software Stata/MP v.16 (The fastest version of Stata). One hundred and fifty-eight studies were selected to review the abstracts, six papers met these crucial criteria to do a systematic review and meta-analysis. Sensitivity and specificity of digital periapical radiography was 50% (ES 0.50; 95% CI 0.05, 0.95) and 83% (ES 0.83; 95% CI 0.52, 1.15), respectively. Sensitivity and specificity of cone-beam computed tomographic was 95% (ES 0.95; 95% CI 0.80, 1.00) and 90% (ES 0.90; 95% CI 0.78, 1.03), respectively. In conclusion, CBCT imaging reports values with excellent accuracy vs digital periapical radiography.

Keywords: Apical periodontitis; Cone-beam CT; Periapical radiography.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Orstavik D. Essential endodontology: prevention and treatment of apical periodontitis. John Wiley & Sons; 2020.
    1. Endres MG, Hillen F, Salloumis M, Sedaghat AR, Niehues SM, Quatela O, et al. Development of a deep learning algorithm for periapical disease detection in dental radiographs. Diagnostics. 2020;10(6):430. - DOI
    1. Arslan ZB, Demir H, Berker Yıldız D, Yaşar F. Diagnostic accuracy of panoramic radiography and ultrasonography in detecting periapical lesions using periapical radiography as a gold standard. Dentomaxillofacial Radiology. 2020;49:20190290. - DOI
    1. Katebzadeh N, Hupp J, Trope M. Histological periapical repair after obturation of infected root canals in dogs. J Endodo. 1999;25(5):364–8. - DOI
    1. Bender I, Seltzer S. Roentgenographic and direct observation of experimental lesions in bone: II. J Endod. 1961;29(11):707–12. - DOI