Biomechanics of below-knee amputee gait
- PMID: 3417688
- DOI: 10.1016/0021-9290(88)90142-x
Biomechanics of below-knee amputee gait
Abstract
Sagittal plane biomechanical and EMG analyses from eight below knee (B/K) amputee trials demonstrate considerably modified motor patterns from the residual muscles at the hip and knee. Five SACH fittings, two Uniaxial and one Gressinger prostheses were analysed. Moments of force and mechanical power were analysed on all eight trials and EMG profiles are reported for three of the amputees fitted with SACH prostheses. The findings can be summarized as follows: 1. All eight trials had similar internal moment of force patterns at the ankle. A dorsiflexor moment commenced at heel contact and continued for the first third of stance. The prostheses generated a plantarflexor moment for the balance of stance which increased in late stance to about 2/3 that seen in normals. 2. The two Uniaxial prostheses showed a 20% recovery of stored energy which was returned at push-off. The recovery by the Gressinger fitting was 30%. 3. For all but the Gressinger prosthesis the knee moment of force was negligible during early stance (when normals have an extensor moment), below normal in late stance and fairly normal during swing. The amputee wearing the Gressinger prosthesis had a normal but slightly reduced pattern of moments of force over the entire stride. 4. All eight trials had hyperactive hip extensors during early and mid-stance which resulted in above-normal energy generation by these concentrically contracting muscles. This compensation makes up for the loss of the major energy generation by the plantarflexors at push-off. 5. The moment of force and power patterns at the hip for all eight trials during late stance and swing were fairly normal.(ABSTRACT TRUNCATED AT 250 WORDS)
Similar articles
-
Contributions to the understanding of gait control.Dan Med J. 2014 Apr;61(4):B4823. Dan Med J. 2014. PMID: 24814597 Review.
-
Joint moment and muscle power output characteristics of below knee amputees during running: the influence of energy storing prosthetic feet.J Biomech. 1991;24(1):63-75. doi: 10.1016/0021-9290(91)90327-j. J Biomech. 1991. PMID: 2026634
-
Dynamics of below-knee child amputee gait: SACH foot versus Flex foot.J Biomech. 1993 Oct;26(10):1191-204. doi: 10.1016/0021-9290(93)90067-o. J Biomech. 1993. PMID: 8253824
-
Gait patterns of elderly men with trans-tibial amputations.Prosthet Orthot Int. 1993 Apr;17(1):27-37. doi: 10.3109/03093649309164352. Prosthet Orthot Int. 1993. PMID: 8337098 Review.
-
Analysis of mechanical and metabolic factors in the gait of congenital below knee amputees. A comparison of the SACH and Seattle feet.Am J Phys Med Rehabil. 1992 Oct;71(5):272-8. doi: 10.1097/00002060-199210000-00004. Am J Phys Med Rehabil. 1992. PMID: 1388973
Cited by
-
Effects of powered versus passive-elastic ankle foot prostheses on leg muscle activity during level, uphill and downhill walking.R Soc Open Sci. 2022 Dec 14;9(12):220651. doi: 10.1098/rsos.220651. eCollection 2022 Dec. R Soc Open Sci. 2022. PMID: 36533194 Free PMC article.
-
Multi-degrees-of-freedom soft robotic ankle-foot orthosis for gait assistance and variable ankle support.Wearable Technol. 2022;3:e18. doi: 10.1017/wtc.2022.14. Epub 2022 Aug 1. Wearable Technol. 2022. PMID: 36721460 Free PMC article.
-
Differences in gait characteristics between persons with bilateral transtibial amputations, due to peripheral vascular disease and trauma, and able-bodied ambulators.Arch Phys Med Rehabil. 2008 Jul;89(7):1386-94. doi: 10.1016/j.apmr.2007.10.050. Arch Phys Med Rehabil. 2008. PMID: 18586143 Free PMC article.
-
Effects of physical exertion on trans-tibial prosthesis users' ability to accommodate alignment perturbations.Prosthet Orthot Int. 2016 Feb;40(1):75-82. doi: 10.1177/0309364614545419. Epub 2014 Aug 19. Prosthet Orthot Int. 2016. PMID: 25138114 Free PMC article.
-
Comparison of Rectified and Unrectified Sockets for Transtibial Amputees.J Prosthet Orthot. 2008;18(1):1-7. doi: 10.1097/00008526-200601000-00002. J Prosthet Orthot. 2008. PMID: 18776945 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical