Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2021 Jun 30;13(13):2165.
doi: 10.3390/polym13132165.

High-Power LED Units Currently Available for Dental Resin-Based Materials-A Review

Affiliations
Review

High-Power LED Units Currently Available for Dental Resin-Based Materials-A Review

Rita Almeida et al. Polymers (Basel). .

Abstract

The pursuit of less time-consuming procedures led to the development of high-power light-curing-units (LCU) to light-cure dental-resin-based-materials. This review aims to describe high-power light-emitting-diode (LED)-LCUs, by a bibliometric systematization of in vitro and in vivo studies. The research-question, by PICO model, aimed to assess the current knowledge on dentistry-based high-power LED-LCUs by analyzing to what extent their use can promote adverse events on materials and patients' oral condition when compared to low-power LED-LCUs, on daily dental practice. PubMed and B-on database search focused on high-power (≥2000 mW/cm2) LED-LCUs outputs. Studies assessing performance of high-power LED-LCUs for light-curing dental-resin-based-materials were included. From 1822 screened articles, 21 fulfilled the inclusion criteria. Thirty-two marketed units with high levels of radiant emittance (≥2000 mW/cm2 up to 6000 mW/cm2) were identified. Most output values vary on 2000-3000 mW/cm2. The highest output found was 6000 mW/cm2, in FlashMaxP3. Reports suggest that light-curing protocols with lower emittance irradiance and longer exposure outperforms all other combination, however in some clinical procedures high-power LED-LCUs are advocated when compared to low-power LED-LCUs. Moreover, long time exposures and over-curing can be dangerous to the biological vital pulp, and other oral tissues. Evidence showing that high-power LCUs are the best clinical option is still very scarce.

Keywords: LED curing-lights; adverse events; composite resins; dental curing units; dental materials.

PubMed Disclaimer

Conflict of interest statement

The authors declare no conflict of interest.

Figures

Figure 1
Figure 1
Search flowchart according to PRISMA illustrating study inclusion.

References

    1. Santini A. Current Status of Visible Light Activation Units and the Curing of Light-activated Resin-based Composite Materials. Dent. Update. 2010;37:123. doi: 10.12968/denu.2010.37.4.214. - DOI - PubMed
    1. Price R.B., Ferracane J.L., Shortall A.C. Light-Curing Units: A Review of What We Need to Know. J. Dent Res. 2015;94:1179–1186. doi: 10.1177/0022034515594786. - DOI - PubMed
    1. Delgado A.J., Castellanos E.M., Coelho Sinhoreti M.A., de Oliveira D.C.R.S., Abdulhameed N., Geraldeli S., Sulaiman T.A., Roulet J.-F. The use of different photoinitiator systems in photopolymerizing resin cements through ceramic veneers. Oper. Dent. 2019;44:396–404. doi: 10.2341/17-263-L. - DOI - PubMed
    1. Brandt W.C., Schneider L.F.J., Frollini E., Correr-Sobrinho L., Sinhoreti M.A.C. Effect of different photo-initiators and light curing units on degree of conversion of composites. Braz. Oral Res. 2010;24:263–270. doi: 10.1590/S1806-83242010000300002. - DOI - PubMed
    1. Pratap B., Gupta R.K., Bhardwaj B., Nag M. Resin based restorative dental materials: Characteristics and future perspectives. Jpn. Dent. Sci. Rev. 2019;55:126–138. doi: 10.1016/j.jdsr.2019.09.004. - DOI - PMC - PubMed

LinkOut - more resources