Report of AAPM Task Group 219 on independent calculation-based dose/MU verification for IMRT

Affiliations
Review

Report of AAPM Task Group 219 on independent calculation-based dose/MU verification for IMRT

Timothy C Zhu et al. Med Phys. 2021 Oct.

Erratum in

Abstract

Independent verification of the dose per monitor unit (MU) to deliver the prescribed dose to a patient has been a mainstay of radiation oncology quality assurance (QA). We discuss the role of secondary dose/MU calculation programs as part of a comprehensive QA program. This report provides guidelines on calculation-based dose/MU verification for intensity modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT) provided by various modalities. We provide a review of various algorithms for "independent/second check" of monitor unit calculations for IMRT/VMAT. The report makes recommendations on the clinical implementation of secondary dose/MU calculation programs; on commissioning and acceptance of various commercially available secondary dose/MU calculation programs; on benchmark QA and periodic QA; and on clinically reasonable action levels for agreement of secondary dose/MU calculation programs.

PubMed Disclaimer

References

REFERENCES

    1. Gibbons JP, Antolak JA, Followill DS, et al. Report of the AAPM Therapy Physics Committee Task Group. No. 71. Med Phys. 2014;41(3):031501.
    1. Stern RL, Heaton R, Fraser MW, et al. Verification of monitor unit calculations for non-IMRT clinical radiotherapy: report of AAPM Task Group 114. Med Phys. 2011;38(1):504-530.
    1. Boyer AL, Butler EB, DiPetrillo TA, et al. Intensity-modulated radiotherapy: current status and issues of interest. Int J Rad Onc Biol Phys. 2001;51(4):880-914.
    1. Moran JM, Dempsey M, Eisbruch A, et al. Safety considerations for IMRT: executive summary. Med Phys. 2011;38(9):5067-5072.
    1. Fraass BA, Marks LB, Pawlicki T. Commentary: safety considerations in contemporary radiation oncology: introduction to a series of ASTRO safety white papers. Prac Rad Onc. 2011;1(3):188-189.

LinkOut - more resources