Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2021 Nov;94(5):881-889.e5.
doi: 10.1016/j.gie.2021.06.028. Epub 2021 Jul 1.

Contrast-enhanced EUS for the characterization of mural nodules within pancreatic cystic neoplasms: systematic review and meta-analysis

Affiliations
Meta-Analysis

Contrast-enhanced EUS for the characterization of mural nodules within pancreatic cystic neoplasms: systematic review and meta-analysis

Andrea Lisotti et al. Gastrointest Endosc. 2021 Nov.

Abstract

Background and aims: Pancreatic cystic neoplasms (PCNs) carry a considerable malignancy risk. Along with main duct dilation, the presence of enhanced mural nodules represents a significant risk factor for malignancy. Several articles assessed the role of contrast-enhanced EUS (CE-EUS) for the identification of malignant features in mural nodules. We evaluate the pooled diagnostic performance of CE-EUS for the identification of high-grade dysplasia or invasive carcinoma among mural nodules in PCNs.

Methods: A systematic review (Medline, PubMed, EMBASE) and meta-analysis were conducted. Subgroup analysis was used to assess the usefulness of a dedicated contrast-harmonic (CH-EUS). The primary outcome was pooled sensitivity for identification of high-grade dysplasia or invasive carcinoma.

Results: Ten studies (532 patients) were included. Pooled sensitivity of CE-EUS was 88.2% (95% confidence interval [CI], 82.7%-92.5%), specificity 79.1% (95% CI, 74.5%-83.3%), and diagnostic accuracy 89.6% (95% CI, 83.4%-95.8%). Eight studies (320 patients) were conducted using CH-EUS: pooled sensitivity increased to 97.0% (95% CI, 92.5%-99.2%), specificity to 90.4% (95% CI, 85.2%-94.2%), and diagnostic accuracy to 95.6% (95% CI, 92.6%-98.7%). At 42% disease prevalence (pretest probability), a positive CH-EUS increased the disease probability to 88%, whereas a negative test decreased the disease probability to 2%. The number needed to diagnose was 1.5 (95% CI, 1.7-1.3) for CE-EUS and just 1.2 (95% CI, 1.3-1.1) for CH-EUS.

Conclusions: This study provided robust evidence on CE-EUS value for the characterization of mural nodules within PCNs. A dedicated contrast-harmonic mode, namely CH-EUS, provided an increased diagnostic yield in the identification and characterization of malignant mural nodules.

PubMed Disclaimer

Comment in

LinkOut - more resources