Mass spectrometry with derivatization method for concurrent measurement of amino acids and acylcarnitines in plasma of diabetic type 2 patients with diabetic nephropathy
- PMID: 34222079
- PMCID: PMC8212236
- DOI: 10.1007/s40200-021-00786-3
Mass spectrometry with derivatization method for concurrent measurement of amino acids and acylcarnitines in plasma of diabetic type 2 patients with diabetic nephropathy
Abstract
Background: Amino acids (AAs) and acylcarnitines play a key role in metabolic disease and can be used as biomarkers of various diseases such as malignancies, type 2 diabetes (T2D), insulin resistance, and cardiovascular diseases, therefore, designing an accurate and simple laboratory method that simultaneously measure both groups of substances, could improve the process of analytes quantification. In this research, a flow injection tandem mass spectrometry (FI-MS/MS) method for simultaneous measurement of AAs and acylcarnitines in addition to results of validation is explained.
Methods: Samples were mixed with internal standards and after derivatization (with butanolic-HCL), AAs, and acylcarnitines were quantified by tandem mass spectrometry (SCIEX API 3200). Analytical performance studies were designed based on the Clinical and Laboratory Standards Institute (CLSI) guidelines including precision, accuracy, linearity, and limit of detection-quantification (LOD-LOQ) experiments. Samples from patients with T2D in different stages of kidney disease were also analyzed to ensure the clinical usage of the method.
Results: Performance evaluation of the method demonstrated adequate results. The mean of estimated inter-assay precision (reported as a coefficient variation) for AAs and acylcarnitines were less than 8.7% and 12.3%, the estimated mean bias was below 8.8% and 10.2% respectively. LOD of analytes ranged between 0.6-10 μmol per liter (μmol/L) for AAs and 0.02-1 μmol/L for acylcarnitines. LOQ analytes showed a range of 2-25 μmol/L and 0.05-5 μmol/L for AAs and carnitine/acylcarnitines respectively. In diabetic patients sample analysis, a significant increase in acylcarnitines (C2, C4, C5DC, C6, C8, C10, C14) and citrulline with a significant decrease in valine were seen in patients with severely increased albuminuria.
Conclusion: FI-MS/MS method with pre-injection derivatization with butanolic-HCL can be used for concurrent measurement of AAs and carnitine/acylcarnitines in a short time and it satisfies the analytical performance requirements. This method is applied for AAs and carnitine/acylcarnitines measurement in patient with T2DM and results show some of the acylcarnitines and AAs can be involved in diabetic nephropathy development.
Supplementary information: The online version contains supplementary material available at 10.1007/s40200-021-00786-3.
Keywords: Acylcarnitine; Amino acid; Carnitine; Diabetes; Nephropathy; Tandem mass spectrometry.
© Springer Nature Switzerland AG 2021.
Conflict of interest statement
Conflict of interestThe authors declare that they have no conflict of interest.
Similar articles
-
Measurement of free carnitine and acylcarnitines in plasma by HILIC-ESI-MS/MS without derivatization.J Chromatogr B Analyt Technol Biomed Life Sci. 2013 Aug 1;932:12-8. doi: 10.1016/j.jchromb.2013.05.028. Epub 2013 Jun 2. J Chromatogr B Analyt Technol Biomed Life Sci. 2013. PMID: 23816563
-
A clinically validated method to separate and quantify underivatized acylcarnitines and carnitine metabolic intermediates using mixed-mode chromatography with tandem mass spectrometry.J Chromatogr A. 2022 Jan 25;1663:462749. doi: 10.1016/j.chroma.2021.462749. Epub 2021 Dec 16. J Chromatogr A. 2022. PMID: 34954532
-
A HILIC-MS/MS method development and validation for the quantitation of 13 acylcarnitines in human serum.Anal Bioanal Chem. 2022 Apr;414(9):3095-3108. doi: 10.1007/s00216-022-03940-9. Epub 2022 Feb 17. Anal Bioanal Chem. 2022. PMID: 35178602
-
Identification and assay of underivatized urinary acylcarnitines by paper spray tandem mass spectrometry.Anal Bioanal Chem. 2013 Oct;405(25):8267-76. doi: 10.1007/s00216-013-7232-3. Epub 2013 Aug 2. Anal Bioanal Chem. 2013. PMID: 23907684
-
Rapid measurement of plasma acylcarnitines by liquid chromatography-tandem mass spectrometry without derivatization.Clin Chim Acta. 2005 Aug;358(1-2):104-12. doi: 10.1016/j.cccn.2005.02.011. Epub 2005 Apr 9. Clin Chim Acta. 2005. PMID: 16018880
Cited by
-
Targeted metabolomics analysis of amino acids and acylcarnitines as risk markers for diabetes by LC-MS/MS technique.Sci Rep. 2022 May 19;12(1):8418. doi: 10.1038/s41598-022-11970-7. Sci Rep. 2022. PMID: 35589736 Free PMC article.
-
Metabolomic Signature of Diabetic Kidney Disease in Cerebrospinal Fluid and Plasma of Patients with Type 2 Diabetes Using Liquid Chromatography-Mass Spectrometry.Diagnostics (Basel). 2022 Oct 29;12(11):2626. doi: 10.3390/diagnostics12112626. Diagnostics (Basel). 2022. PMID: 36359470 Free PMC article.
-
Association of plasma acylcarnitines and amino acids with hypertension: A nationwide metabolomics study.PLoS One. 2023 Jan 17;18(1):e0279835. doi: 10.1371/journal.pone.0279835. eCollection 2023. PLoS One. 2023. PMID: 36649284 Free PMC article. Clinical Trial.
-
Metabolic signatures of insulin resistance in non-diabetic individuals.BMC Endocr Disord. 2022 Aug 24;22(1):212. doi: 10.1186/s12902-022-01130-3. BMC Endocr Disord. 2022. PMID: 36002887 Free PMC article.
-
Application of Metabolomics in Various Types of Diabetes.Diabetes Metab Syndr Obes. 2022 Jul 13;15:2051-2059. doi: 10.2147/DMSO.S370158. eCollection 2022. Diabetes Metab Syndr Obes. 2022. PMID: 35860310 Free PMC article. Review.
References
LinkOut - more resources
Full Text Sources
Miscellaneous