Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Nov;62(6):591-597.
doi: 10.1016/j.pedneo.2021.05.021. Epub 2021 Jun 19.

Measurement of optic nerve sheath diameter by ultrasound in healthy term neonates

Affiliations
Free article

Measurement of optic nerve sheath diameter by ultrasound in healthy term neonates

Shih-Yun Lan et al. Pediatr Neonatol. 2021 Nov.
Free article

Abstract

Background: Optic nerve sheath diameter (ONSD) ultrasound is a noninvasive and repeatable tool to dynamically evaluate intracranial pressure with high diagnostic accuracy; however, data in neonates are scarce. The aim of this study was to determine the reference value of ONSD and potential influencing factors in healthy term neonates.

Methods: We retrospectively reviewed 250 full-term neonates who underwent cranial ultrasound as part of selective newborn screening over a 2-year period. Neonates with any of the following conditions were excluded: using mechanical ventilation, sedatives and/or vasopressors, or signs of infection which needed cerebrospinal fluid analysis and/or intracranial pathologies. Data on sex, gestational age, birth body weight, birth body height, birth head circumference, Apgar score and types of delivery were collected. The neurodevelopmental outcomes were reviewed.

Results: A total of 234 neonates (123 girls and 111 boys) were included. The mean ONSD value was 3.30 ± 0.27 mm in the right eye and 3.30 ± 0.23 mm in the left eye, with no significant difference between both eyes (p = 0.797). Male neonates had a larger ONSD than female neonates (3.34 ± 0.22 mm versus 3.26 ± 0.20 mm, p = 0.007), and ONSD was correlated with birth weight in the males. Otherwise, there were no statistically significant associations between ONSD and other birth characteristics in both sexes. Most (63%) cases were followed for at least 12 months, and 98% had normal neurodevelopment.

Conclusion: The reference value reported in this study may be used to evaluate the ONSD in healthy term neonates. Sex differences should be considered in this age group.

Keywords: cranial ultrasound; intracranial pressure; neonate; optic nerve sheath diameter; reference value.

PubMed Disclaimer

Conflict of interest statement

Declaration of competing interest The authors declare no competing interests.

LinkOut - more resources