Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1988 Jan;26(1):111-5.
doi: 10.1128/jcm.26.1.111-115.1988.

Quantification of immunoglobulin on electrophoretic immunoblot strips as a tool for human immunodeficiency virus serodiagnosis

Affiliations

Quantification of immunoglobulin on electrophoretic immunoblot strips as a tool for human immunodeficiency virus serodiagnosis

J Blomberg et al. J Clin Microbiol. 1988 Jan.

Abstract

Electrophoretic immunoblotting (EIB [Western blotting]), the main method for verification of human immunodeficiency virus (HIV) seropositivity, needs thorough characterization and standardization. We explored the possibilities of quantifying immunoglobulin G (IgG) bound to EIB strips both by densitometry of the peroxidase-stained bands and by measurement of radioactivity with labeled anti-HIV IgG. The radioactivity method is inherently more exact but was more cumbersome. However, despite saturation phenomena at high IgG densities, the densitometric method was more convenient and yielded reproducible estimates of the amount of bound IgG. We found it useful primarily for documentation of changes in the relative abundance of antibodies to different HIV proteins from individual patients over time. To explore the potential usefulness of the method, we studied a small set of HIV-seropositive persons. The average p24/gp41 color yield ratios and standard deviations in 3 persons with recent seroconversion, 15 healthy subjects, and 6 diseased HIV-seropositive persons were 6.6 +/- 0.9, 2.3 +/- 1.9, and 1.3 +/- 0.5, respectively. These data are in accord with previous qualitative or semiquantitative observations but are too limited for any conclusions regarding the use of quantitative EIB for prognostic use with individual patients. Quantitative EIB is a valuable tool for comparative methodological studies and for research on the protective role of anti-HIV antibodies in acquired immunodeficiency syndrome pathogenesis. Its possible use in prognostication for individual patients must be evaluated in long-term studies.

PubMed Disclaimer

References

    1. J Infect Dis. 1986 Apr;153(4):736-42 - PubMed
    1. Br Med J (Clin Res Ed). 1986 Jan 25;292(6515):228-30 - PubMed
    1. Biochem Biophys Res Commun. 1986 Mar 28;135(3):778-84 - PubMed
    1. Infect Immun. 1986 Jul;53(1):124-8 - PubMed
    1. JAMA. 1986 Jul 18;256(3):347 - PubMed