Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2022 Jun;14(6):558-563.
doi: 10.1136/neurintsurg-2021-017751. Epub 2021 Jul 7.

Device size selection can enhance Y-stentrieving efficacy and safety as a rescue strategy in stroke thrombectomy

Affiliations

Device size selection can enhance Y-stentrieving efficacy and safety as a rescue strategy in stroke thrombectomy

Lucas Scotta Cabral et al. J Neurointerv Surg. 2022 Jun.

Abstract

Background: Despite advancements in stroke treatment, refractory clots are relatively common, prompting the exploration of alternative techniques. Bifurcation occlusions pose specific intraprocedural challenges, occasionally dealt with by two stentrievers deployed in Y-configuration. Previous studies have portrayed this strategy as feasible, yet little is known about its safety and efficacy, and how to best select retrievers.

Objective: To determine whether device selection influences the efficacy and safety of Y-stentrieving.

Methods: We performed a multicentric, retrospective analysis of patients undergoing Y-stentrieving rescue for bifurcation occlusions. Demographics, devices, procedural metrics, neurological severity, reperfusion, disability, and safety were assessed.

Results: Y-configuration stents were used as a rescue maneuver after 2.16±1.5 failed attempts with other techniques in 20 patients. Successful reperfusion (modified Thrombolysis in Cerebral Infarction score 2b-3) was achieved in 70% of patients after the first Y-stentrieving attempt. The first stentriever more often had a larger diameter (5.15±0.92 vs 3.67±0.57 mm, p=0.017) and longer length (33.12±5.78 vs 20.67±1.15 mm, p=0.002) in successfully reperfused cases. Also, the diameter of the first device was associated with both any parenchymal (6.0 vs 4.71±0.99 mm, p=0.045) and symptomatic (6.0 vs 4.86±1.02 mm, p<0.001) hemorrhages. Exact logistic regression demonstrated that a longer length first stentriever independently predicted better angiographic outcomes (OR=1.26, p=0.036), and a 6 mm diameter first stentriever independently predicted more intracranial hemorrhages (OR=15.28, p=0.044). No periprocedural mortality was recorded.

Conclusion: Y-stentrieving is an effective and safe bail-out strategy for refractory bifurcation clots. Longer stents may promote better angiographic outcomes, whereas avoidance of disproportionately large retrievers may mitigate intracranial hemorrhage. Future studies should account for these factors when evaluating alternative stentriever techniques.

Keywords: device; stroke; thrombectomy.

PubMed Disclaimer

Conflict of interest statement

Competing interests: LSC reports presentation honoraria from Penumbra Inc. MMB is supported by National Council for Scientific and Technological Development (CNPq). RGN reports consulting fees for advisory roles with Anaconda, Biogen, Cerenovus, Genentech, Imperative Care, Hybernia, Medtronic, Phenox, Prolong Pharmaceuticals, Stryker Neurovascular, Synchron, and stock options for advisory roles with Astrocyte, Brainomix, Cerebrotech, Ceretrieve, Corindus Vascular Robotics, Vesalio, Viz-AI, and Perfuze. The other authors have not reported any competing interests.