Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Sep;9(5):1467-1480.
doi: 10.1111/andr.13077. Epub 2021 Sep 23.

X-ray micro-computed tomography in the assessment of penile cavernous fibrosis in a rabbit castration model

Affiliations
Free article

X-ray micro-computed tomography in the assessment of penile cavernous fibrosis in a rabbit castration model

Mikhail I Kogan et al. Andrology. 2021 Sep.
Free article

Abstract

Background: Current assessment methods of penile cavernous fibrosis in animal models have limitations due to the inability to provide complex and volume analysis of fibrotic alterations.

Objective: The aim was to evaluate micro-computed tomography for assessment of cavernous fibrosis and compare it with histological, histochemical, immunohistochemical, and RT-PCR analysis.

Materials and methods: A controlled trial was performed involving 25 New Zealand male rabbits with induced testosterone deficiency by orchidectomy. Penile samples were obtained before and after 7, 14, 21, and 84 days from orchidectomy. We consistently performed (a) gray value analysis of corpora cavernosa 3D models reconstructed after micro-computed tomography, (b) morphometry of smooth muscles/connective tissue ratio, collagen type I/III ratio, and area of TGF-beta-1 expression in corpora cavernosa, and (c) RT-PCR of TGF-beta-1 expression.

Results: Micro-computed tomography allowed visualization of penile structures at a resolution comparable to light microscopy. Gray values of corpora cavernosa decreased from 1673 (1512-1773) on the initial day to 1184 (1089-1232) on the 21st day (p < 0.005). However, on the 84th day, it increased to 1610 (1551-1768). On 21st and 84th days, there was observed a significant decrease in smooth muscle/connective tissue ratio and a significant increase in collagen type I/III ratio (p < 0.05). TGF-beta1 expression increased on the 84th day according to immunohistochemistry (p < 0.005). RT-PCR was impossible to conduct due to the absence of RNA in obtained samples after micro-CT.

Discussion and conclusions: Micro-computed tomography provided 3D visualization of entire corpora cavernosa and assessment of radiodensity alterations by gray value analysis in fibrosis progression. We speculate that gray value changes at early and late fibrosis stages could be related to tissue reorganization. RT-PCR is impossible to conduct on tissue samples studied by micro-CT due to RNA destruction. We also suggest that micro-computed tomography could negatively affect the immunohistochemical outcome, as a significant increase of TGF-beta-1 expression occurs later than histological fibrotic signs.

Keywords: 3D X-ray microscopy; animal model; cavernous fibrosis; corpora cavernosa; gray value analysis; micro-computed tomography; penis; radiodensity.

PubMed Disclaimer

References

REFERENCES

    1. Yafi FA, Jenkins L, Albersen M, et al. Erectile dysfunction. Nat Rev Dis Prim. 2016;2:16003.
    1. Mobley DF, Khera M, Baum N. Recent advances in the treatment of erectile dysfunction. Postgrad Med J. 2017;93(1105):679-685.
    1. Bertolotto M, Campo I, Sachs C, et al. Sonography of the penis/erectile dysfunction. Abdom Radiol. 2020;45(7):1973-1989.
    1. Ma M, Yu B, Qin F, Yuan J. Current approaches to the diagnosis of vascular erectile dysfunction. Transl Androl Urol. 2020;9(2):709-721.
    1. Cho MC, Song WH, Paick J. Suppression of cavernosal fibrosis in a rat model. Sex Med Rev. 2018;6(4):572-582.

Publication types

Substances

LinkOut - more resources