Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Aug 14;13(30):3433-3443.
doi: 10.1039/d1ay00793a. Epub 2021 Jul 14.

Assessment of trace levels of aflatoxins AFB1 and AFB2 in non-dairy beverages by molecularly imprinted polymer based micro solid-phase extraction and liquid chromatography-tandem mass spectrometry

Affiliations

Assessment of trace levels of aflatoxins AFB1 and AFB2 in non-dairy beverages by molecularly imprinted polymer based micro solid-phase extraction and liquid chromatography-tandem mass spectrometry

Anis Chmangui et al. Anal Methods. .

Abstract

A selective molecularly imprinted polymer (MIP) adsorbent was synthesised and used in a batch micro-solid phase extraction format for isolating aflatoxins (AFB1, and AFB2) from non-dairy beverages before liquid chromatography-tandem mass spectrometry determination. MIP synthesis (precipitation polymerization in 3 : 1 acetonitrile/toluene as a porogen) was performed with 5,7-dimethoxycoumarin (DMC), methacrylic acid (MAA) and divinylbenzene-80 (DVB) as a dummy template, functional monomer and cross-linker, respectively (1 : 4 : 20 molar ratio). 2,2'-Azobisisobutyronitrile (AIBN) was used as a polymerization initiator. The adsorbent MIP (50 mg) was enclosed in a cone-shaped polypropylene membrane (porous membrane protected molecularly imprinted micro-solid phase extraction), and parameters such as sample pH, mechanical (orbital-horizontal) shaking, the extraction time (loading stage), the composition of the eluting solution, and the desorption time were optimised. The highest extraction yields were obtained by using 5 mL of non-dairy beverages (pH adjusted at 6.0), and mechanical shaking (150 rpm) for 15 min. Elution was performed with 5 mL of an acetonitrile/formic acid (97.5 : 2.5) mixture under ultrasound (325 W, 35 kHz) for 15 min. After eluate evaporation to dryness and re-dissolution in 150 μL of the mobile phase, the pre-concentration factor of the method was 33.3, which yields limits of detection within the 0.085-0.207 μg L-1 range. In addition, the current proposal was shown to be an accurate and precise method through relative standard deviation of intraday and inter-day assays below 18% and analytical recoveries in the range of 91-104%. However, the method was found to suffer from matrix effects.

PubMed Disclaimer

Publication types

LinkOut - more resources