Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Jun;11(3):292-298.
doi: 10.1016/j.jpha.2020.11.004. Epub 2020 Nov 19.

Dispersive liquid-liquid microextraction, an effective tool for the determination of synthetic cannabinoids in oral fluid by liquid chromatography-tandem mass spectrometry

Affiliations

Dispersive liquid-liquid microextraction, an effective tool for the determination of synthetic cannabinoids in oral fluid by liquid chromatography-tandem mass spectrometry

Pierpaolo Tomai et al. J Pharm Anal. 2021 Jun.

Abstract

In the present work, dispersive liquid-liquid microextraction (DLLME) was used to extract six synthetic cannabinoids (JWH-018, JWH-019, JWH-073, JWH-200, or WIN 55,225, JWH-250, and AM-694) from oral fluids. A rapid baseline separation of the analytes was achieved on a bidentate octadecyl silica hydride phase (Cogent Bidentate C18; 4.6 mm × 250 mm, 4 μm) maintained at 37 °C, by eluting in isocratic conditions (water:acetonitrile (25:75, V/V)). Detection was performed using positive electrospray ionization-tandem mass spectrometry. The parameters affecting DLLME (pH and ionic strength of the aqueous phase, type and volume of the extractant and dispersive solvent, vortex and centrifugation time) were optimized for maximizing yields. In particular, using 0.5 mL of oral fluid, acetonitrile (1 mL), was identified as the best option, both as a solvent to precipitate proteins and as a dispersing solvent in the DLLME procedure. To select an extraction solvent, a low transition temperature mixture (LTTM; composed of sesamol and chlorine chloride with a molar ratio of 1:3) and dichloromethane were compared; the latter (100 μL) was proved to be a better extractant, with recoveries ranging from 73% to 101 % by vortexing for 2 min. The method was validated according to the guidelines of Food and Drug Administration bioanalytical methods: intra-day and inter-day precisions ranged between 4 % and 18 % depending on the spike level and analyte; limits of detection spanned from 2 to 18 ng/mL; matrix-matched calibration curves were characterized by determination coefficients greater than 0.9914. Finally, the extraction procedure was compared with previous methods and with innovative techniques, presenting superior reliability, rapidity, simplicity, inexpensiveness, and efficiency.

Keywords: Dispersive liquid-liquid microextraction; Illicit drugs; Microextraction techniques; Silica C-based column; Synthetic cannabinoids.

PubMed Disclaimer

Conflict of interest statement

The authors declare that there are no conflicts of interest.

Figures

Image 1
Graphical abstract
Fig. 1
Fig. 1
Structures, exact masses and log P of the synthetic cannabinoids selected for this study.
Fig. 2
Fig. 2
Chromatographic separation of the selected cannabinoids on (A) a bidentate C18 silica hydride phase and on (B) an end-capped C18 stationary phase.
Fig. 3
Fig. 3
Comparison between two DLLME procedures based on the use of chloroform and the deep eutectic solvent chlorine chloride(sesamol)3 as extractants. In this case, the chlorinated solvent offers better recovery yields for most analytes. DLLME: dispersive liquid-liquid microextraction.

References

    1. Debruyne D., Le Boisselier R. Emerging drugs of abuse: current perspectives on synthetic cannabinoids. Subst. Abuse Rehabil. 2015;6:113–129. - PMC - PubMed
    1. Huffman J.W., Dai D., Martin B.R. Design, synthesis and pharmacology of cannabimimetic indoles. Bioorg. Med. Chem. Lett. 1994;4:563–566.
    1. Favretto D., Pascali J.P., Tagliaro F. New challenges and innovation in forensic toxicology: focus on the “New Psychoactive Substances”. J. Chromatogr. A. 2013;1287:84–95. - PubMed
    1. Seely K.A., Lapoint J., Moran J.H. Spice drugs are more than harmless herbal blends: a review of the pharmacology and toxicology of synthetic cannabinoids. Prog. Neuro-Psychopharmacol. Biol. Psychiatry. 2012;39:234–243. - PMC - PubMed
    1. Schaefer N., Kettner M., Laschke M.W. Simultaneous LC-MS/MS determination of JWH-210, RCS-4, Δ (9)-tetrahydrocannabinol, and their main metabolites in pig and human serum, whole blood, and urine for comparing pharmacokinetic data. Anal. Bioanal. Chem. 2015;407:3775–3786. - PubMed

LinkOut - more resources