A dynamic susceptibility contrast MRI digital reference object for testing software with leakage correction: Effect of background simulation

Affiliations

A dynamic susceptibility contrast MRI digital reference object for testing software with leakage correction: Effect of background simulation

Henry Szu-Meng Chen et al. Med Phys. 2021 Oct.

Abstract

Purpose: Dynamic susceptibility contrast (DSC)-MRI is a perfusion imaging technique from which useful quantitative imaging biomarkers can be derived. Relative cerebral blood volume (rCBV) is such a biomarker commonly used for evaluating brain tumors. To account for the extravasation of contrast agents in tumors, post-processing leakage correction is often applied to improve rCBV accuracy. Digital reference objects (DRO) are ideal for testing the post-processing software, because the biophysical model used to generate the DRO can be matched to the one that the software uses. This study aims to develop DROs to validate the leakage correction of software using Weisskoff model and to examine the effect of background signal time curves that are required by the model.

Methods: Three DROs were generated using the Weisskoff model, each composed of nine foreground lesion objects with combinations of different levels of rCBV and contrast leakage parameter (K2). Three types of background were implemented for these DROs: (1) a multi-compartment brain-like background, (2) a sphere background with a constant signal time curve, and (3) a sphere background with signal time curve identical to that of the brain-like DRO's white matter (WM). The DROs were then analyzed with an FDA-cleared software with and without leakage correction. Leakage correction was tested with and without brain segmentation.

Results: Accuracy of leakage correction was able to be verified using the brain-like phantom and the sphere phantom with WM background. The sphere with constant background did not perform well with leakage correction with or without brain segmentation. The DROs were able to verify that for the particular software tested, leakage correction with brain segmentation achieved the lowest error.

Conclusions: DSC-MRI DROs with biophysical model matched to that of the post-processing software can be well used for the software's validation, provided that the background signals are also properly simulated for generating the reference time curve required by the model. Care needs to be taken to consider the interaction of the design of the DRO with the software's implementation of brain segmentation to extract the reference time curve.

Keywords: DRO; DSC; MRI; digital phantom; digital reference object; dynamic susceptibility contrast; quality assurance.

PubMed Disclaimer

Similar articles

Cited by

References

REFERENCES

    1. Rempp KA, Brix G, Wenz F, Becker CR, Gückel F, Lorenz WJ. Quantification of regional cerebral blood flow and volume with dynamic susceptibility contrast-enhanced MR imaging. Radiology. 1994;193(3):637-641. https://doi.org/10.1148/radiology.193.3.7972800
    1. Hu LS, Baxter LC, Smith KA, et al. Relative cerebral blood volume values to differentiate high-grade glioma recurrence from posttreatment radiation effect: direct correlation between image-guided tissue histopathology and localized dynamic susceptibility-weighted contrast-enhanced perfusion MR imaging measurements. Am J Neuroradiol. 2009;30(3):552-558. https://doi.org/10.3174/ajnr.A1377
    1. Essig M, Nguyen TB, Shiroishi MS, et al. Perfusion MRI: the five most frequently asked clinical questions. AJR Am J Roentgenol. 2013;201(3):W495-W510. https://doi.org/10.2214/AJR.12.9544
    1. Boxerman JL, Schmainda KM, Weisskoff RM. Relative cerebral blood volume maps corrected for contrast agent extravasation significantly correlate with glioma tumor grade, whereas uncorrected maps do not. Am J Neuroradiol. 2006;27(4):859-867.
    1. Hu LS, Kelm Z, Korfiatis P, et al. Impact of software modeling on the accuracy of perfusion MRI in glioma. Am J Neuroradiol. 2015;36(12):2242-2249. https://doi.org/10.3174/ajnr.A4451

LinkOut - more resources