Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Oct;23(10):2723-2730.
doi: 10.1111/codi.15845. Epub 2021 Aug 22.

Diagnostic accuracy of C-reactive protein, procalcitonin and neutrophils for the early detection of anastomotic leakage after colorectal resection: a multicentric, prospective study

Collaborators, Affiliations

Diagnostic accuracy of C-reactive protein, procalcitonin and neutrophils for the early detection of anastomotic leakage after colorectal resection: a multicentric, prospective study

Angela Sala Hernandez et al. Colorectal Dis. 2021 Oct.

Abstract

Aim: The aim was to determine the accuracy of C-reactive protein (CRP), procalcitonin and neutrophils in the early detection (fourth postoperative day) of anastomotic leakage (AL) after colorectal surgery.

Methods: We conducted a multicentre, prospective study that included a consecutive series of patients who underwent colorectal resection with anastomosis without ostomy (September 2015 to December 2017). CRP, procalcitonin and neutrophil values on the fourth postoperative day after colorectal resection along with the postoperative outcome (60-day AL, morbidity and mortality) were prospectively included in an online, anonymous database.

Results: The analysis ultimately included 2501 cases. The overall morbidity and mortality was 30.1% and 1.6%, respectively, and the AL rate was 8.6%. The area under the receiver operating characteristic curve values (95% CI) for detecting AL were 0.84 (0.81-0.87), 0.75 (0.72-0.79) and 0.70 (0.66-0.74) for CRP, procalcitonin and neutrophils, respectively. The best cut-off level for CRP was 119 mg/l, resulting in 70% sensitivity, 81% specificity and 97% negative predictive value. After laparoscopic resection, the accuracy for CRP and procalcitonin was increased, compared with open resection. The combination of two or three of these biomarkers did not significantly increase their accuracy.

Conclusion: On the fourth postoperative day, CRP was the most reliable marker for excluding AL. Its high negative predictive value, especially after laparoscopic resection, allows for safe hospital discharge on the fourth postoperative day. The routine use of procalcitonin or neutrophil counts does not seem to increase the diagnostic accuracy.

Keywords: C-reactive protein; anastomotic leakage; biomarkers; colorectal surgery; neutrophils; procalcitonin.

PubMed Disclaimer

References

REFERENCES

    1. Platell C, Barwood N, Dorfmann G, Makin G. The incidence of anastomotic leaks in patients undergoing colorectal surgery. Colorectal Dis. 2006;9(1):71-9.
    1. Phitayakorn R, Delaney CP, Reynolds HL, Champagne BJ, Heriot AG, Neary P, et al. Standardized algorithms for management of anastomotic leaks and related abdominal and pelvic abscesses after colorectal surgery. World J Surg. 2008;32(6):1147-56.
    1. Almeida AB, Faria G, Moreira H, Pinto-de-Sousa J, Correia-da-Silva P, Maia JC. Elevated serum C-reactive protein as a predictive factor for anastomotic leakage in colorectal surgery. Int J Surg. 2012;10(2):87-91.
    1. García-Granero A, Frasson M, Flor-Lorente B, Blanco F, Puga R, Carratalá A, et al. Procalcitonin and C-reactive protein as early predictors of anastomotic leak in colorectal surgery: a prospective observational study. Dis Colon Rectum. 2013;56(4):475-83.
    1. Lagoutte N, Facy O, Ravoire A, Chalumeau C, Jonval L, Rat P, et al. C-reactive protein and procalcitonin for the early detection of anastomotic leakage after elective colorectal surgery: pilot study in 100 patients. J Visc Surg. 2012;149(5):345-9.