Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Multicenter Study
. 2021 Sep 15:155:64-71.
doi: 10.1016/j.amjcard.2021.06.020. Epub 2021 Jul 25.

Longitudinal Outcomes Associated With Non-Evidence-Based Implantable Cardioverter-Defibrillators Among Medicare Beneficiaries (From the National Cardiovascular Data Registry)

Affiliations
Multicenter Study

Longitudinal Outcomes Associated With Non-Evidence-Based Implantable Cardioverter-Defibrillators Among Medicare Beneficiaries (From the National Cardiovascular Data Registry)

Usama A Daimee et al. Am J Cardiol. .

Abstract

Primary prevention implantable cardioverter-defibrillators (ICDs) in patients with recent myocardial infarction or coronary revascularization and those with newly diagnosed or severe heart failure (HF) are considered non-evidence-based, as defined by pivotal randomized clinical trials. Although non-evidence-based ICDs have been associated previously with greater risk of in-hospital adverse events, longitudinal outcomes are not known. We used Medicare-linked data from the National Cardiovascular Data Registry's ICD Registry to identify patients discharged alive following first-time primary prevention ICD implantations performed between 2010 and 2013. We compared longitudinal outcomes, including all-cause mortality and all-cause hospital readmission among patients receiving non-evidence-based versus evidence-based ICDs, up to 4.75 years after implantation, using multivariable time-to-event analyses. Of 71,666 ICD implantations, 9,609 (13.4%) were classified as non-evidence-based. Compared to patients receiving evidence-based ICDs, non-evidence-based ICD recipients had greater mortality risk at 90 days (HR = 1.44, CI: 1.37 - 1.52, p <0.0001) and at 1 year (HR = 1.19, CI: 1.15 - 1.24, p <0.0001), but similar mortality risk at 3 years (HR = 1.03, CI: 0.98 - 1.08, p = 0.2630). Risk of all-cause hospitalization was higher in patients with non-evidence-based ICDs at 90 days (HR = 1.17, CI: 1.14 - 1.20, p <0.0001), but the difference diminished at 1 year (HR = 1.04, CI 1.00 - 1.07, p = 0.0272) and at 3 years (HR = 0.94, CI: 0.90 - 0.99, p = 0.0105). In conclusion, among patients undergoing primary prevention ICD implantations between 2010 and 2013, those with non-evidence-based ICDs were at increased risk of mortality and readmission during longitudinal follow-up. Differences in the risk of mortality and hospitalization were highest in the first year following device implantation.

PubMed Disclaimer

Publication types