Geometric accuracy of magnetic resonance imaging-derived virtual 3-dimensional bone surface models of the mandible in comparison to computed tomography and cone beam computed tomography: A porcine cadaver study
- PMID: 34318580
- DOI: 10.1111/cid.13033
Geometric accuracy of magnetic resonance imaging-derived virtual 3-dimensional bone surface models of the mandible in comparison to computed tomography and cone beam computed tomography: A porcine cadaver study
Abstract
Background: Providing accurate 3-dimensional virtual bone surface models is a prerequisite for virtual surgical planning and additive manufacturing in craniomaxillofacial surgery. For this purpose, magnetic resonance imaging (MRI) may be a radiation-free alternative to computed tomography (CT) and cone beam computed tomography (CBCT).
Purpose: The aim of this study was to assess the geometric accuracy of 3-dimensional T1-weighted MRI-derived virtual bone surface models of the mandible in comparison to CT and CBCT.
Materials and methods: Specimens of the mandible from porcine cadavers were scanned with (1) a 3-dimensional T1-weighted MRI sequence (0.6 mm isotropic voxel) optimized for bone imaging, (2) CT, and (3) CBCT. Cortical mandibular structures (n = 10) were segmented using semiautomated and manual techniques. Imaging-based virtual 3-dimensional models were aligned with a high-resolution optical 3-dimensional surface scan of the dissected bone (=ground truth) and global geometric deviations were calculated (mean surface distance [MSD]/root-mean-square distance [RMSD]). Agreement between the imaging modalities was assessed by equivalence testing and Bland-Altman analysis.
Results: Intra- and inter-rater agreement was on a high level for all modalities. Global geometric deviations (MSD/RMSD) between optical scans and imaging modalities were 0.225 ± 0.020 mm/0.345 ± 0.074 mm for CT, 0.280 ± 0.067 mm/0.371 ± 0.074 mm for MRI, and 0.352 ± 0.076 mm/0.454 ± 0.071 mm for CBCT. All imaging modalities were statistically equivalent within an equivalence margin of ±0.3 mm, and Bland-Altman analysis indicated high agreement as well.
Conclusions: The results of this study indicate that the accuracy and reliability of MRI-derived virtual 3-dimensional bone surface models is equal to CT and CBCT. MRI may be considered as a reliable alternative to CT and CBCT in computer-assisted craniomaxillofacial surgery.
Keywords: CAD/CAM; additive manufacturing; computer-assisted surgery; craniomaxillofacial surgery; dental imaging; guided-implant surgery; image processing; implant surgery; magnetic resonance imaging; radiology.
© 2021 The Authors. Clinical Implant Dentistry and Related Research Published by Wiley Periodicals LLC.
References
REFERENCES
-
- Elnagar MH, Aronovich S, Kusnoto B. Digital workflow for combined orthodontics and orthognathic surgery. Oral Maxillofac Surg Clin North Am. 2020;32(1):1-14.
-
- Deeb GR, Tran DQ, Deeb JG. Computer-aided planning and placement in implant surgery. Atlas Oral Maxillofac Surg Clin North Am. 2020;28(2):53-58.
-
- Tahmaseb A, Wu V, Wismeijer D, Coucke W, Evans C. The accuracy of static computer-aided implant surgery: a systematic review and meta-analysis. Clin Oral Implants Res. 2018;29(Suppl 16):416-435.
-
- Amundson M, Newman M, Cheng A, Khatib B, Cuddy K, Patel A. Three-dimensional computer-assisted surgical planning, manufacturing, intraoperative navigation, and computed tomography in maxillofacial trauma. Atlas Oral Maxillofac Surg Clin North Am. 2020;28(2):119-127.
-
- van Baar GJC, Forouzanfar T, Liberton N, Winters HAH, Leusink FKJ. Accuracy of computer-assisted surgery in mandibular reconstruction: a systematic review. Oral Oncol. 2018;84:52-60.