Effect of Extrinsic Warming of Low-Osmolality CT Contrast Media (Iohexol 350) on Extravasations and Patient Reaction Rates: A Retrospective Study
- PMID: 34319163
- DOI: 10.2214/AJR.21.26256
Effect of Extrinsic Warming of Low-Osmolality CT Contrast Media (Iohexol 350) on Extravasations and Patient Reaction Rates: A Retrospective Study
Abstract
BACKGROUND. Extrinsic warming of iodinated CT contrast media to body temperature reduces viscosity and injection pressures. However, studies examining the effect of extrinsic warming on clinical adverse events are limited in number and provide conflicting results. Therefore, consensus practice recommendations have been sparse. OBJECTIVE. The purpose of this study is to compare rates of extravasation, allergic and allergiclike reactions, and physiologic reactions between iohexol 350 mg I/mL warmed to body temperature (37°C) versus this agent maintained at room temperature. METHODS. This retrospective study compared adult patients who received CT examinations using IV iohexol 350 that had either been warmed to body temperature or maintained at room temperature. At our institution, contrast media had historically been warmed to body temperature before a protocol change unrelated to this investigation. Information on the patient and CT examination was extracted from the electronic medical record. Adverse events, including extravasations, allergic and allergiclike reactions, and physiologic reactions, were compared between groups. RESULTS. A total of 3939 patients received contrast media warmed to body temperature before the protocol change; 3933 patients received contrast media at room temperature after the protocol change. The body temperature group experienced 11 (0.28%; 95% CI, 0.14-0.50%) adverse events, all extravasations; the allergic and allergic-like reaction rate was 0.00% (97.5% CI, 0.00-0.09%). The room temperature group experienced 17 (0.43%; 95% CI, 0.25-0.69%) adverse events: 13 (0.33%; 95% CI, 0.17-0.56%) extravasations and four (0.10%; 95% CI, 0.03-0.26%) allergic and allergiclike reactions. No physiologic reaction occurred in either group. The two groups were not different in terms of overall reaction rate (p = .19), extravasation rate (p = .69), allergic and allergiclike reaction rate (p = .06), or physiologic reaction rate (p > .99). Logistic regression adjusting for patient and CT characteristics (age, sex, conventional CT vs CTA, contrast media volume, injection location) showed no significant association of patient group and adverse reaction rate (odds ratio, 2.19; 95% CI, 0.68-7.00). Multivariable regression modeling showed an excess of 0.27 adverse events per 100 patients within the room temperature group, which is below a 0.6% noninferiority margin. CONCLUSION. The data suggest that maintaining iohexol 350 at room temperature is noninferior to warming the agent to body temperature before injection. CLINICAL IMPACT. The resources involved to prewarm iohexol 350 before injection may not be warranted.
Keywords: adverse events; allergiclike reactions; contrast media; extravasation; physiologic reactions.
Comment in
-
Editorial Comment: Has the Time Come Not to Prewarm Iodinated Contrast Media Before Injection for CT?AJR Am J Roentgenol. 2022 Jan;218(1):179. doi: 10.2214/AJR.21.26648. Epub 2021 Aug 11. AJR Am J Roentgenol. 2022. PMID: 34378400 No abstract available.
Similar articles
-
Additional use of extrinsic warmer for intravenous CT contrast media and its impact on incidence of contrast extravasations and allergic like reactions: a prospective observational case control study.Clin Radiol. 2024 Nov;79(11):851-860. doi: 10.1016/j.crad.2024.08.013. Epub 2024 Aug 20. Clin Radiol. 2024. PMID: 39277429
-
Rate of contrast material extravasations and allergic-like reactions: effect of extrinsic warming of low-osmolality iodinated CT contrast material to 37 degrees C.Radiology. 2012 Feb;262(2):475-84. doi: 10.1148/radiol.11111282. Epub 2011 Nov 21. Radiology. 2012. PMID: 22106356 Free PMC article.
-
Extrinsic warming of low-osmolality iodinated contrast media to 37°C reduced the rate of allergic-like reaction.Allergy Asthma Proc. 2018 Nov 1;39(6):e55-e63. doi: 10.2500/aap.2018.39.4160. Allergy Asthma Proc. 2018. PMID: 30401329 Free PMC article.
-
The relationship between iodinated contrast material temperature and adverse reactions: A meta-analysis of 307,329 injections.Clin Imaging. 2023 Aug;100:54-59. doi: 10.1016/j.clinimag.2023.05.006. Epub 2023 May 18. Clin Imaging. 2023. PMID: 37216743
-
Contrast media extravasations in patients undergoing computerized tomography scanning: a systematic review and meta-analysis of risk factors and interventions.JBI Database System Rev Implement Rep. 2018 Jan;16(1):87-116. doi: 10.11124/JBISRIR-2017-003348. JBI Database System Rev Implement Rep. 2018. PMID: 29324560 Free PMC article.
Cited by
-
Incidence, outcome, and risk factors of contrast media extravasation injury during contrast-enhanced computed tomography scans: an observational cohort study.Quant Imaging Med Surg. 2025 Aug 1;15(8):7338-7351. doi: 10.21037/qims-24-2332. Epub 2025 Jul 25. Quant Imaging Med Surg. 2025. PMID: 40785883 Free PMC article.
-
Ultrasound-Guided Dorsolateral Approach for Quadratus Lumborum Block in Rabbits (Oryctolagus cuniculus): A Prospective, Randomized, Blinded, Cadaveric Study Comparing Four Different Injectate Volumes.Animals (Basel). 2023 Aug 8;13(16):2559. doi: 10.3390/ani13162559. Animals (Basel). 2023. PMID: 37627351 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical