Objectives: For listeners with one deaf ear and the other ear with normal/near-normal hearing (single-sided deafness [SSD]) or moderate hearing loss (asymmetric hearing loss), cochlear implants (CIs) can improve speech understanding in noise and sound-source localization. Previous SSD-CI localization studies have used a single source with artificial sounds such as clicks or random noise. While this approach provides insights regarding the auditory cues that facilitate localization, it does not capture the complex nature of localization behavior in real-world environments. This study examined SSD-CI sound localization in a complex scenario where a target sound was added to or removed from a mixture of other environmental sounds, while tracking head movements to assess behavioral strategy.
Design: Eleven CI users with normal hearing or moderate hearing loss in the contralateral ear completed a sound-localization task in monaural (CI-OFF) and bilateral (CI-ON) configurations. Ten of the listeners were also tested before CI activation to examine longitudinal effects. Two-second environmental sound samples, looped to create 4- or 10-sec trials, were presented in a spherical array of 26 loudspeakers encompassing ±144° azimuth and ±30° elevation at a 1-m radius. The target sound was presented alone (localize task) or concurrently with one or three additional sources presented to different loudspeakers, with the target cued by being added to (Add) or removed from (Rem) the mixture after 6 sec. A head-mounted tracker recorded movements in six dimensions (three for location, three for orientation). Mixed-model regression was used to examine target sound-identification accuracy, localization accuracy, and head movement. Angular and translational head movements were analyzed both before and after the target was switched on or off.
Results: Listeners showed improved localization accuracy in the CI-ON configuration, but there was no interaction with test condition and no effect of the CI on sound-identification performance. Although high-frequency hearing loss in the unimplanted ear reduced localization accuracy and sound-identification performance, the magnitude of the CI localization benefit was independent of hearing loss. The CI reduced the magnitude of gross head movements used during the task in the azimuthal rotation and translational dimensions, both while the target sound was present (in all conditions) and during the anticipatory period before the target was switched on (in the Add condition). There was no change in pre- versus post-activation CI-OFF performance.
Conclusions: These results extend previous findings, demonstrating a CI localization benefit in a complex listening scenario that includes environmental and behavioral elements encountered in everyday listening conditions. The CI also reduced the magnitude of gross head movements used to perform the task. This was the case even before the target sound was added to the mixture. This suggests that a CI can reduce the need for physical movement both in anticipation of an upcoming sound event and while actively localizing the target sound. Overall, these results show that for SSD listeners, a CI can improve localization in a complex sound environment and reduce the amount of physical movement used.
Copyright © 2021 Wolters Kluwer Health, Inc. All rights reserved.
Conflict of interest statement
The authors have no conflicts of interest to disclose.
Similar articles
-
Effects of Head Movements on Sound-Source Localization in Single-Sided Deaf Patients With Their Cochlear Implant On Versus Off.Ear Hear. 2020 Nov/Dec;41(6):1660-1674. doi: 10.1097/AUD.0000000000000882. Ear Hear. 2020. PMID: 33136640 Free PMC article.
-
Sound Source Localization and Speech Understanding in Complex Listening Environments by Single-sided Deaf Listeners After Cochlear Implantation.Otol Neurotol. 2015 Sep;36(9):1467-71. doi: 10.1097/MAO.0000000000000841. Otol Neurotol. 2015. PMID: 26375967 Free PMC article.
-
Acoustic Hearing Can Interfere With Single-Sided Deafness Cochlear-Implant Speech Perception.Ear Hear. 2020 Jul/Aug;41(4):747-761. doi: 10.1097/AUD.0000000000000805. Ear Hear. 2020. PMID: 31584504 Free PMC article.
-
Postoperative optimization of cochlear implantation for single sided deafness and asymmetric hearing loss: a systematic review.Cochlear Implants Int. 2023 Nov;24(6):342-353. doi: 10.1080/14670100.2023.2239512. Epub 2023 Jul 25. Cochlear Implants Int. 2023. PMID: 37490782
-
American Cochlear Implant Alliance Task Force Guidelines for Clinical Assessment and Management of Adult Cochlear Implantation for Single-Sided Deafness.Ear Hear. 2022 Nov-Dec 01;43(6):1605-1619. doi: 10.1097/AUD.0000000000001260. Epub 2022 Aug 22. Ear Hear. 2022. PMID: 35994570 Free PMC article.
Cited by
-
Task force Guideline of Brazilian Society of Otology - hearing loss in children - Part II - Treatment.Braz J Otorhinolaryngol. 2023 Jan-Feb;89(1):190-206. doi: 10.1016/j.bjorl.2022.11.001. Epub 2022 Nov 26. Braz J Otorhinolaryngol. 2023. PMID: 36528468 Free PMC article. Review.
-
The Effect of Sound Localization on Auditory-Only and Audiovisual Speech Recognition in a Simulated Multitalker Environment.Trends Hear. 2023 Jan-Dec;27:23312165231186040. doi: 10.1177/23312165231186040. Trends Hear. 2023. PMID: 37415497 Free PMC article.
-
Single-Sided Deafness and Cochlear Implants: Performance in a Novel Combined Speech-in-Noise and Localization Task.Otol Neurotol. 2025 Jul 16:10.1097/MAO.0000000000004537. doi: 10.1097/MAO.0000000000004537. Online ahead of print. Otol Neurotol. 2025. PMID: 40689936 Free PMC article.
-
Etiology, Severity, Audiogram Type, and Device Usage in Patients with Unilateral Moderate to Profound Sensorineural Hearing Loss in Japan.J Clin Med. 2023 Jun 26;12(13):4290. doi: 10.3390/jcm12134290. J Clin Med. 2023. PMID: 37445325 Free PMC article.
-
Free-Field Hearing Test in Noise with Free Head Rotation for Evaluation of Monaural Hearing.J Clin Med. 2023 Nov 17;12(22):7143. doi: 10.3390/jcm12227143. J Clin Med. 2023. PMID: 38002755 Free PMC article.
References
-
- American National Standards Institute. (Maximum Permissible Ambient Noise Levels for Audiometric Test Rooms, S3.1. (1999). American National Standards Institute.
-
- Arndt S., Aschendorff A., Laszig R., Beck R., Schild C., Kroeger S., Ihorst G., Wesarg T. Comparison of pseudobinaural hearing to real binaural hearing rehabilitation after cochlear implantation in patients with unilateral deafness and tinnitus. Otol Neurotol, (2011). 32, 39–47.
-
- Arndt S., Laszig R., Aschendorff A., Hassepass F., Beck R., Wesarg T. Cochlear implant treatment of patients with single-sided deafness or asymmetric hearing loss. HNO, (2017). 65(Suppl 2), 98–108.
-
- Baguley D. M., Bird J., Humphriss R. L., Prevost A. T. The evidence base for the application of contralateral bone anchored hearing aids in acquired unilateral sensorineural hearing loss in adults. Clin Otolaryngol, (2006). 31, 6–14.
-
- Bernstein J. G., Goupell M. J., Schuchman G. I., Rivera A. L., Brungart D. S. Having two ears facilitates the perceptual separation of concurrent talkers for bilateral and single-sided deaf cochlear implantees. Ear Hear, (2016). 37, 289–302.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous