Doppler determination of cardiac output in infants and children: comparison with simultaneous thermodilution
Abstract
Ten children, aged six weeks to 13 years, without intracardiac shunts or lesions that could cause turbulent flow in the ascending aorta or aortic regurgitation, underwent cardiac catheterization, including cardiac output measurements by thermodilution. Simultaneously with each of six consecutive thermodilution injections, mean and maximal blood velocities in the ascending aorta were measured by pulsed Doppler echocardiography from the suprasternal notch. Aortic root and aortic orifice diameters were measured with M-mode and cross-sectional echocardiography. One patient had to be excluded from the analysis because of inadequate Doppler recordings. The best agreement with the results of the thermodilution was observed when internal systolic aortic root diameter was combined with mean velocity (r = 0.97, y = 0.90x + 0.28, SEE = 0.31 liters/min). When cardiac output was normalized for body size, there was still a good correlation between the results of these two methods.
Similar articles
-
Superiority of two-dimensional measurement of aortic vessel diameter in Doppler echocardiographic estimates of left ventricular stroke volume.J Am Coll Cardiol. 1985 Jul;6(1):66-74. doi: 10.1016/s0735-1097(85)80255-2. J Am Coll Cardiol. 1985. PMID: 4008789
-
Influence of sampling site and flow area on cardiac output measurements by Doppler echocardiography.J Am Coll Cardiol. 1987 Oct;10(4):818-23. doi: 10.1016/s0735-1097(87)80275-9. J Am Coll Cardiol. 1987. PMID: 3655148
-
Stroke volume measured by pulsed ultrasound Doppler and M-mode echocardiography.Acta Anaesthesiol Scand. 1983 Dec;27(6):454-7. doi: 10.1111/j.1399-6576.1983.tb01986.x. Acta Anaesthesiol Scand. 1983. PMID: 6666522
-
Determination of stroke volume and cardiac output during exercise: comparison of two-dimensional and Doppler echocardiography, Fick oximetry, and thermodilution.Circulation. 1987 Sep;76(3):539-47. doi: 10.1161/01.cir.76.3.539. Circulation. 1987. PMID: 3621519
-
[Noninvasive measurement of cardiac output by pulsed Doppler echocardiography. Correlation with thermodilution].Arch Mal Coeur Vaiss. 1990 Feb;83(2):237-44. Arch Mal Coeur Vaiss. 1990. PMID: 2106860 Review. French.
Cited by
-
Comparison of three non-invasive hemodynamic monitoring methods in critically ill children.PLoS One. 2018 Jun 18;13(6):e0199203. doi: 10.1371/journal.pone.0199203. eCollection 2018. PLoS One. 2018. PMID: 29912937 Free PMC article.
-
The Ratio Fallacy, with Special Reference to the Cardiac Index.Pediatr Cardiol. 2018 Apr;39(4):805-809. doi: 10.1007/s00246-018-1823-x. Epub 2018 Feb 1. Pediatr Cardiol. 2018. PMID: 29387918
-
The haemodynamic effects of umbilical cord milking in term infants: a randomised controlled trial.Singapore Med J. 2023 Jul;64(7):439-443. doi: 10.11622/smedj.2022041. Singapore Med J. 2023. PMID: 35366660 Free PMC article. Clinical Trial.
-
Reproducibility of measurements of cardiac output in newborn infants by Doppler ultrasound.Arch Dis Child. 1990 Jan;65(1 Spec No):15-9. doi: 10.1136/adc.65.1_spec_no.15. Arch Dis Child. 1990. PMID: 2407197 Free PMC article.
-
Mean or maximum velocity using pulsed Doppler ultrasound in determination of Doppler-derived cardiac output in the newborn infant.Med Biol Eng Comput. 1993 Jan;31(1):58-60. doi: 10.1007/BF02446894. Med Biol Eng Comput. 1993. PMID: 8326765 No abstract available.
References
Publication types
MeSH terms
LinkOut - more resources