Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2022 Mar 1;48(3):280-287.
doi: 10.1097/j.jcrs.0000000000000743.

Comparison of refractive and visual outcomes of 3 presbyopia-correcting intraocular lenses

Affiliations

Comparison of refractive and visual outcomes of 3 presbyopia-correcting intraocular lenses

Tiago B Ferreira et al. J Cataract Refract Surg. .

Abstract

Purpose: To evaluate and compare the clinical outcomes after cataract surgery with implantation of 3 types of trifocal diffractive intraocular lenses (IOLs).

Setting: Hospital da Luz, Lisbon, Portugal.

Design: Prospective comparative case series.

Methods: Patients undergoing phacoemulsification cataract surgery with implantation of 1 of the 3 trifocal IOLs were enrolled: TECNIS Synergy (Synergy group, 30 patients), Acrysof PanOptix (PanOptix group, 30 patients), and POD F (Finevision group, 30 patients). The outcomes of distance, intermediate, and near visual acuity (VA), refraction, defocus curve, photic phenomena, and spectacle independence were evaluated at the 3-month follow-up.

Results: 180 eyes of 90 patients were enrolled. No statistically significant differences were found between groups in monocular distance-corrected intermediate (Synergy group 0.04 ± 0.11, PanOptix group 0.05 ± 0.09, and Finevision group 0.08 ± 0.10; P = .107) and near VA (0.01 ± 0.08, 0.01 ± 0.06, and 0.04 ± 0.10, respectively; P = .186). Similarly, no statistically significant differences among groups were found in binocular uncorrected distance (P = .572), near (P = .929), and intermediate VA (P = .327). By contrast, statistically significant differences between groups were found in the visual acuity for the vergence demands of -0.50, -1.00, -2.00, -3.50, and -4.00 diopters (P ≤ .045). No statistically significant differences among groups were found in the frequency, severity, and bothersomeness of different disturbing visual symptoms, including glare and halos (P ≥ .129). More than 87 (96%) of patients in all groups did not require the use of spectacles at any distance postoperatively.

Conclusions: The 3 trifocal IOLs evaluated provided an effective visual rehabilitation with minimal incidence of photic phenomena. A trend to obtain a wider range of functional focus was observed with the TECNIS Synergy IOL.

PubMed Disclaimer

References

    1. Sieburth R, Chen M. Intraocular lens correction of presbyopia. Taiwan J Ophthalmol 2019;9:4–17
    1. Kohnen T, Marchini G, Alfonso JF, Bala C, Cochener B, Martinez A, Carreño E. Innovative trifocal (quadrifocal) presbyopia-correcting IOLs: 1-year outcomes from an international multicenter study. J Cataract Refract Surg 2020;46:1142–1148
    1. Royo M, Jiménez Á, Piñero DP. Clinical outcomes of cataract surgery with implantation of a continuous transitional focus intraocular lens. J Cataract Refract Surg 2020;460:567–572
    1. Serdiuk V, Ustymenko S, Fokina S, Ivantsov I. Comparison of three different presbyopia-correcting intraocular lenses. Rom J Ophthalmol 2020;64:364–379
    1. Lapid-Gortzak R, Bhatt U, Sanchez JG, Guarro M, Hida WT, Bala C, Nosé RM, Rodriguez Alvira FJ, Martinez A. Multicenter visual outcomes comparison of 2 trifocal presbyopia-correcting IOLs: 6-month postoperative results. J Cataract Refract Surg 2020;46:1534–1542

LinkOut - more resources