Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Sep 1;131(3):1176-1185.
doi: 10.1152/japplphysiol.01059.2020. Epub 2021 Jul 29.

The effect of minimal differences in the skin-to-air vapor pressure gradient at various dry-bulb temperatures on self-paced exercise performance

Affiliations
Free article

The effect of minimal differences in the skin-to-air vapor pressure gradient at various dry-bulb temperatures on self-paced exercise performance

Felicity M Bright et al. J Appl Physiol (1985). .
Free article

Abstract

The effects of dry-bulb temperature on self-paced exercise performance, along with thermal, cardiovascular, and perceptual responses, were investigated by minimizing differences in the skin-to-air vapor pressure gradient (Psk,sat - Pa) between four temperatures. Fourteen trained male cyclists performed 30-km time trials in 13°C and 44% relative humidity (RH), 20°C and 70% RH, 28°C and 78% RH, and 36°C and 72% RH. Power output was similar in 13°C (275 ± 31 W; means and SD) and 20°C (272 ± 28 W; P = 1.00), lower in 36°C (228 ± 36 W) than 13°C, 20°C, and 28°C (262 ± 27 W; P < 0.001) and lower in 28°C than at 13°C and 20°C (P < 0.001). Peak rectal temperature was higher in 36°C (39.6 ± 0.4°C) than in all conditions (P < 0.001) and higher in 28°C (39.1 ± 0.4°C) than 13°C (38.7 ± 0.3°C; P < 0.001) and 20°C (38.8 ± 0.3°C; P < 0.01). Mean heart rate was higher in 36°C (163 ± 14 beats·min-1) than all conditions (P < 0.001) and higher in 20°C (156 ± 11 beats·min-1; P = 0.009) and 28°C (159 ± 11 beats·min-1; P < 0.001) than 13°C (153 ± 11 beats·min-1). Mean cardiac output was lower in 36°C (16.8 ± 2.5 L·min-1) than all conditions (P < 0.001) and lower in 28°C (18.6 ± 1.6 L·min-1) than 20°C (19.4 ± 2.0 L·min-1; P = 0.004). Ratings of perceived exertion were higher in 36°C than all conditions (P < 0.001) and higher in 28°C than 20°C (P < 0.04). Self-paced exercise performance was maintained in 13°C and 20°C at a matched evaporative potential, impaired in 28°C, and further compromised in 36°C in association with a moderately lower evaporative potential and marked elevations in thermal, cardiovascular, and perceptual strain.NEW & NOTEWORTHY This is the first study to investigate the effects of dry-bulb temperature (13, 20, 28, and 36°C) on self-paced exercise performance by minimizing differences in the skin-to-air vapor pressure gradient (i.e., evaporative potential) between conditions. Performance was similar in 13°C and 20°C with a matched evaporative potential, whereas it was reduced at 28°C and further impaired at 36°C in association with a large decrease in dry heat loss and moderate reduction in evaporative potential.

Keywords: ambient temperature; cardiovascular strain; cycling; self-paced exercise; thermal strain; time trial.

PubMed Disclaimer

Comment in

LinkOut - more resources