1.5 vs 3 Tesla Magnetic Resonance Imaging: A Review of Favorite Clinical Applications for Both Field Strengths-Part 1
- PMID: 34324464
- DOI: 10.1097/RLI.0000000000000812
1.5 vs 3 Tesla Magnetic Resonance Imaging: A Review of Favorite Clinical Applications for Both Field Strengths-Part 1
Abstract
Whole-body magnetic resonance imaging (MRI) systems with a field strength of 3 T have been offered by all leading manufacturers for approximately 2 decades and are increasingly used in clinical diagnostics despite higher costs. Technologically, MRI systems operating at 3 T have reached a high standard in recent years, as well as the 1.5-T devices that have been in use for a longer time. For modern MRI systems with 3 T, more complexity is required, especially for the magnet and the radiofrequency (RF) system (with multichannel transmission). Many clinical applications benefit greatly from the higher field strength due to the higher signal yield (eg, imaging of the brain or extremities), but there are also applications where the disadvantages of 3 T might outweigh the advantages (eg, lung imaging or examinations in the presence of implants). This review describes some technical features of modern 1.5-T and 3-T whole-body MRI systems, and reports on the experience of using both types of devices in different clinical settings, with all sections written by specialist radiologists in the respective fields.This first part of the review includes an overview of the general physicotechnical aspects of both field strengths and elaborates the special conditions of diffusion imaging. Many relevant aspects in the application areas of musculoskeletal imaging, abdominal imaging, and prostate diagnostics are discussed.
Copyright © 2021 Wolters Kluwer Health, Inc. All rights reserved.
Conflict of interest statement
Conflicts of interest and sources of funding: none declared.
References
-
- Soher BJ, Dale BM, Merkle EM. A review of MR physics: 3T versus 1.5T. Magn Reson Imaging Clin N Am . 2007;15:277–90, v.
-
- Schick F. Whole-body MRI at high field: technical limits and clinical potential. Eur Radiol . 2005;15:946–959.
-
- Wright PJ, Mougin OE, Totman JJ, et al. Water proton T1 measurements in brain tissue at 7, 3, and 1.5 T using IR-EPI, IR-TSE, and MPRAGE: results and optimization. MAGMA . 2008;21:121–130.
-
- Gold GE, Han E, Stainsby J, et al. Musculoskeletal MRI at 3.0 T: relaxation times and image contrast. AJR Am J Roentgenol . 2004;183:343–351.
-
- Chang KJ, Kamel IR, Macura KJ, et al. 3.0-T MR imaging of the abdomen: comparison with 1.5 T. Radiographics . 2008;28:1983–1998.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources