Application of Comprehensive Artificial intelligence Retinal Expert (CARE) system: a national real-world evidence study
- PMID: 34325853
- DOI: 10.1016/S2589-7500(21)00086-8
Application of Comprehensive Artificial intelligence Retinal Expert (CARE) system: a national real-world evidence study
Abstract
Background: Medical artificial intelligence (AI) has entered the clinical implementation phase, although real-world performance of deep-learning systems (DLSs) for screening fundus disease remains unsatisfactory. Our study aimed to train a clinically applicable DLS for fundus diseases using data derived from the real world, and externally test the model using fundus photographs collected prospectively from the settings in which the model would most likely be adopted.
Methods: In this national real-world evidence study, we trained a DLS, the Comprehensive AI Retinal Expert (CARE) system, to identify the 14 most common retinal abnormalities using 207 228 colour fundus photographs derived from 16 clinical settings with different disease distributions. CARE was internally validated using 21 867 photographs and externally tested using 18 136 photographs prospectively collected from 35 real-world settings across China where CARE might be adopted, including eight tertiary hospitals, six community hospitals, and 21 physical examination centres. The performance of CARE was further compared with that of 16 ophthalmologists and tested using datasets with non-Chinese ethnicities and previously unused camera types. This study was registered with ClinicalTrials.gov, NCT04213430, and is currently closed.
Findings: The area under the receiver operating characteristic curve (AUC) in the internal validation set was 0·955 (SD 0·046). AUC values in the external test set were 0·965 (0·035) in tertiary hospitals, 0·983 (0·031) in community hospitals, and 0·953 (0·042) in physical examination centres. The performance of CARE was similar to that of ophthalmologists. Large variations in sensitivity were observed among the ophthalmologists in different regions and with varying experience. The system retained strong identification performance when tested using the non-Chinese dataset (AUC 0·960, 95% CI 0·957-0·964 in referable diabetic retinopathy).
Interpretation: Our DLS (CARE) showed satisfactory performance for screening multiple retinal abnormalities in real-world settings using prospectively collected fundus photographs, and so could allow the system to be implemented and adopted for clinical care.
Funding: This study was funded by the National Key R&D Programme of China, the Science and Technology Planning Projects of Guangdong Province, the National Natural Science Foundation of China, the Natural Science Foundation of Guangdong Province, and the Fundamental Research Funds for the Central Universities.
Translation: For the Chinese translation of the abstract see Supplementary Materials section.
Copyright © 2021 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY-NC-ND 4.0 license. Published by Elsevier Ltd.. All rights reserved.
Conflict of interest statement
Declaration of interests JX and XZ report a valid patent (application number CN108596895A; for an eye-fundus image-detection method and device based on machine learning as well as system), which is used for the class 3 medical device of the Chinese National Medical Products Administration (registration number 20203210686; fundus-photography auxiliary-diagnosis software for diabetic retinopathy). All other authors declare no competing interests.
Comment in
-
Real-world validation of artificial intelligence algorithms for ophthalmic imaging.Lancet Digit Health. 2021 Aug;3(8):e463-e464. doi: 10.1016/S2589-7500(21)00140-0. Lancet Digit Health. 2021. PMID: 34325850 No abstract available.
Similar articles
-
Artificial intelligence using deep learning to screen for referable and vision-threatening diabetic retinopathy in Africa: a clinical validation study.Lancet Digit Health. 2019 May;1(1):e35-e44. doi: 10.1016/S2589-7500(19)30004-4. Epub 2019 May 2. Lancet Digit Health. 2019. PMID: 33323239
-
Screening and identifying hepatobiliary diseases through deep learning using ocular images: a prospective, multicentre study.Lancet Digit Health. 2021 Feb;3(2):e88-e97. doi: 10.1016/S2589-7500(20)30288-0. Lancet Digit Health. 2021. PMID: 33509389
-
Development and validation of a deep-learning algorithm for the detection of neovascular age-related macular degeneration from colour fundus photographs.Clin Exp Ophthalmol. 2019 Nov;47(8):1009-1018. doi: 10.1111/ceo.13575. Epub 2019 Jul 25. Clin Exp Ophthalmol. 2019. PMID: 31215760
-
Deep learning versus ophthalmologists for screening for glaucoma on fundus examination: A systematic review and meta-analysis.Clin Exp Ophthalmol. 2021 Dec;49(9):1027-1038. doi: 10.1111/ceo.14000. Epub 2021 Sep 22. Clin Exp Ophthalmol. 2021. PMID: 34506041
-
Progress towards automated diabetic ocular screening: a review of image analysis and intelligent systems for diabetic retinopathy.Med Biol Eng Comput. 2002 Jan;40(1):2-13. doi: 10.1007/BF02347689. Med Biol Eng Comput. 2002. PMID: 11954703 Review.
Cited by
-
Hybrid deep learning models for the screening of Diabetic Macular Edema in optical coherence tomography volumes.Sci Rep. 2024 Jul 31;14(1):17633. doi: 10.1038/s41598-024-68489-2. Sci Rep. 2024. PMID: 39085461 Free PMC article.
-
Enhancing diagnostic accuracy in rare and common fundus diseases with a knowledge-rich vision-language model.Nat Commun. 2025 Jul 1;16(1):5528. doi: 10.1038/s41467-025-60577-9. Nat Commun. 2025. PMID: 40592857 Free PMC article.
-
Evaluation of an Artificial Intelligence System for the Detection of Diabetic Retinopathy in Chinese Community Healthcare Centers.Front Med (Lausanne). 2022 Apr 11;9:883462. doi: 10.3389/fmed.2022.883462. eCollection 2022. Front Med (Lausanne). 2022. PMID: 35479949 Free PMC article.
-
Counteracting Data Bias and Class Imbalance-Towards a Useful and Reliable Retinal Disease Recognition System.Diagnostics (Basel). 2023 May 29;13(11):1904. doi: 10.3390/diagnostics13111904. Diagnostics (Basel). 2023. PMID: 37296756 Free PMC article.
-
International publication trends in the application of artificial intelligence in ophthalmology research: an updated bibliometric analysis.Ann Transl Med. 2023 Mar 15;11(5):219. doi: 10.21037/atm-22-3773. Epub 2023 Mar 9. Ann Transl Med. 2023. PMID: 37007552 Free PMC article. Review.
Publication types
MeSH terms
Associated data
LinkOut - more resources
Full Text Sources
Medical