Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Jul-Sep;35(3):E30-E37.
doi: 10.1097/JPN.0000000000000555.

Comparing JM-105 and MBJ-20 Transcutaneous Bilirubinometers According to the Area Tested in Ethnically Diverse Late-Preterm and Term Neonates

Affiliations

Comparing JM-105 and MBJ-20 Transcutaneous Bilirubinometers According to the Area Tested in Ethnically Diverse Late-Preterm and Term Neonates

Marjan Khajehei et al. J Perinat Neonatal Nurs. 2021 Jul-Sep.

Abstract

This study aims to evaluate the correlation between the results of transcutaneous bilirubin (TcB) levels measured by the 2 transcutaneous bilirubinometers according to the area tested and to compare the TcB measurements and the serum bilirubin (SBR) levels. We screened 78 neonates born at more than 35 weeks of gestation and aged less than 168 hours for jaundice. We used JM-105 and MBJ-20 to measure the TcB at the forehead and the chest. For newborns who had high TcB measurements, we obtained blood samples during the subsequent 30 minutes. There was a strong correlation between the TcB measurements by JM-105 and MBJ-20 and this correlation was stronger when they were used on the sternum. The mean differences between the TcB measurements on the forehead and the sternum and the SBR levels were similar for the JM-105 and the MBJ-20. There was a strong correlation between SBR and the measurements using the 2 devices on the sternum (JM-105: r = 0.805; MBJ-20: r = 0.801), unlike measurements taken on the forehead by each device (r = 0.777 and r = 0.751, respectively). Both devices had high sensitivity and negative predictive values at SBR level of less than 230 μmol/L (<13.4 mg/dL) and high specificity and positive predictive values at SBR level of 230 μmol/L and greater (>13.4mg/dL). Both devices equally overestimated the actual SBR and had more reliable results if used on the sternum.

PubMed Disclaimer

References

    1. Mercier C, Barry S, Paul K, et al. Improving newborn preventive services at the birth hospitalization: a collaborative, hospital-based quality-improvement project. Pediatrics. 2007;120(3):481–488.
    1. Forster D, McLachlan H, Rayner J, Yelland J, Gold L, Rayner S. The early postnatal period: exploring women's views, expectations and experiences of care using focus groups in Victoria, Australia. BMC Pregnancy Childbirth. 2008;8:27.
    1. Olusanya B, Ogunlesi T, Slusher T. Why is kernicterus still a major cause of death and disability in low-income and middle-income countries? Arch Dis Child. 2014;99(12):1117–1121.
    1. Higgins T, Eckfeldt J, Barton J, Doumas B. Hemoglobin, iron and bilirubin. In: Burtis C, Ashwood E, Bruns D, eds. Tietz Textbook of Clinical Chemistry and Molecular Diagnostics. 4th ed. Maryland Heights: MO: Elsevier Saunders; 2012:985–1030.
    1. Maisels M, Ostrea E, Touch S, et al. Evaluation of a New Transcutaneous Bilirubinometer. Pediatrics. 2004;113(6):1628–1635.