Introduction: Carers and comforters frequently remain with children during paediatric general radiographic examinations. As well as improving the likelihood of overall success of the procedure, this can be important for minimising stress and anxiety of the child. Wearing lead aprons can contribute to additional stress and anxiety about the procedure for both carer and child, specifically due to radiation risk. It also introduces some practical challenges for radiographers. This study quantified a carers exposure to scattered radiation for general radiographic examinations when remaining with a child to assist in positioning or to comfort them.
Methods: Scattered radiation was measured at four common locations where a carer may stand, with a range of tube potentials (40 kVp to 100 kVp ) and PMMA thicknesses of 2.5-22.5 cm. This was then matched to our clinical protocols to estimate the radiation dose a carer could be exposed to while assisting a patient during general radiographic examinations.
Results: The effective dose received by a carer standing 20 cm from the centre of the patient varies from 11 min of Australian natural BERT for a finger radiograph on a patient <3 kg and up to 62 h for a swimmers view radiograph performed on a patient >70 kg.
Conclusion: This dosimetric data allowed an evidence-based assessment of radiation protection requirements for the carer using the ALARA principle. At our institution, it was decided that a lead apron is not required if the carer is unlikely to receive more than 2 µSv. A new policy, presented here, was developed to implement this decision.
Keywords: lead apron; paediatric; radiation exposure; radiation protection; radiography.
© 2021 The Royal Australian and New Zealand College of Radiologists.
References
-
- Alexander M. Managing patient stress in pediatric radiology. Radiol Technol 2012; 83: 549-60.
-
- Australian Radiation Protection and Nuclear Safety Agency. Code for Radiation Protection in Medical Exposure, Radiation Protection Series C-5, ARPANSA, Yallambie, 2019.
-
- International Atomic Energy Agency Radiation protection and safety of radiation sources: international basic safety standards, IAEA Safety Standards Series, No. GSR Part 3. European Commission, Food and Agriculture Organization of the United Nations, International Atomic Energy Agency, International Labour Organization, OECD Nuclear Energy Agency, Pan American Health Organization, United Nations Environment Program, World Health Organization (International Atomic Energy Agency, Vienna), 2014.
-
- International Commission of Radiation Protection. The 2007 Recommendations of the International Commission on Radiological Protection, ICRP Publication 103, 2007.
-
- Australian Radiation Protection and Nuclear Safety Agency. Code of Practice for Radiation Protection in the Medical Application of Ionizing Radiation, Radiation Protection Series No. 14, ARPANSA, Yallambie, 2008.
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials