Effect of Acoustic Parameters and Microbubble Concentration on the Likelihood of Encapsulated Microbubble Coalescence
- PMID: 34344561
- PMCID: PMC8547186
- DOI: 10.1016/j.ultrasmedbio.2021.06.020
Effect of Acoustic Parameters and Microbubble Concentration on the Likelihood of Encapsulated Microbubble Coalescence
Abstract
Microbubble contrast agents are commonly used for therapeutic and diagnostic imaging applications. Under certain conditions, these contrast agents can coalesce on ultrasound application and form larger bubbles than the initial population. The formation of large microbubbles potentially influences therapeutic outcomes and imaging quality. We studied clinically relevant ultrasound parameters related to low-pressure therapy and contrast-enhanced ultrasound imaging to determine their effect on microbubble coalescence and subsequent changes in microbubble size distributions in vitro. Results indicate that therapeutic ultrasound at low frequencies, moderate pressures and high duty cycles are capable of forming bubbles greater than two times larger than the initial bubble distribution. Furthermore, acoustic parameters related to contrast-enhanced ultrasound imaging that are at higher frequency, low-pressure and low-duty cycle exhibit no statistically significant changes in bubble diameter, suggesting that standard contrast ultrasound imaging does not cause coalescence. Overall, this work suggests that the microbubble coalescence phenomenon can readily occur at acoustic parameters used in therapeutic ultrasound, generating bubbles much larger than those found in commercial contrast agents, although coalescence is unlikely to be significant in diagnostic contrast-enhanced ultrasound imaging. This observation warrants further expansion of parameter ranges and investigation of resulting effects.
Keywords: Contrast-enhanced ultrasound; Microbubble coalescence; Ultrasound; Ultrasound contrast agent.
Copyright © 2021 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Conflict of interest statement
Conflict of interest disclosure P.A.D. declares co-founder interest in SonoVol, Inc., and Triangle Biotechnology, Inc. Other authors declare no conflict of interest.
Figures
References
-
- Caskey CF, Stieger SM, Qin S, Dayton PA, Ferrara KW. Direct observations of ultrasound microbubble contrast agent interaction with the microvessel wall. J Acoust Soc Am 2007;122:1191–1200. - PubMed
-
- Chomas JE, Dayton P, Allen J, Morgan K, Ferrara KW. Mechanisms of contrast agent destruction. IEEE Trans Ultrason Ferroelectr Freq Control 2001a;48:232–248. Available from: http://ieeexplore.ieee.org/document/896136/ - PubMed
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources