Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Jan;107(1):90-95.
doi: 10.1136/bjophthalmol-2021-319030. Epub 2021 Aug 3.

Accuracy of automated machine learning in classifying retinal pathologies from ultra-widefield pseudocolour fundus images

Affiliations

Accuracy of automated machine learning in classifying retinal pathologies from ultra-widefield pseudocolour fundus images

Fares Antaki et al. Br J Ophthalmol. 2023 Jan.

Abstract

Aims: Automated machine learning (AutoML) is a novel tool in artificial intelligence (AI). This study assessed the discriminative performance of AutoML in differentiating retinal vein occlusion (RVO), retinitis pigmentosa (RP) and retinal detachment (RD) from normal fundi using ultra-widefield (UWF) pseudocolour fundus images.

Methods: Two ophthalmologists without coding experience carried out AutoML model design using a publicly available image data set (2137 labelled images). The data set was reviewed for low-quality and mislabeled images and then uploaded to the Google Cloud AutoML Vision platform for training and testing. We designed multiple binary models to differentiate RVO, RP and RD from normal fundi and compared them to bespoke models obtained from the literature. We then devised a multiclass model to detect RVO, RP and RD. Saliency maps were generated to assess the interpretability of the model.

Results: The AutoML models demonstrated high diagnostic properties in the binary classification tasks that were generally comparable to bespoke deep-learning models (area under the precision-recall curve (AUPRC) 0.921-1, sensitivity 84.91%-89.77%, specificity 78.72%-100%). The multiclass AutoML model had an AUPRC of 0.876, a sensitivity of 77.93% and a positive predictive value of 82.59%. The per-label sensitivity and specificity, respectively, were normal fundi (91.49%, 86.75%), RVO (83.02%, 92.50%), RP (72.00%, 100%) and RD (79.55%,96.80%).

Conclusion: AutoML models created by ophthalmologists without coding experience can detect RVO, RP and RD in UWF images with very good diagnostic accuracy. The performance was comparable to bespoke deep-learning models derived by AI experts for RVO and RP but not for RD.

Keywords: imaging; retina.

PubMed Disclaimer

Conflict of interest statement

Competing interests: None declared.

LinkOut - more resources