Patient-specific instrumentation (PSI) in total ankle arthroplasty: a systematic review
- PMID: 34345975
- DOI: 10.1007/s00264-021-05145-8
Patient-specific instrumentation (PSI) in total ankle arthroplasty: a systematic review
Abstract
Background: Patient-specific instrument (PSI) may theoretically make total ankle arthroplasty (TAA) more accurate. Several studies have reported the outcomes of PSI TAA. The aim of this study is to systematically review the literature of PSI TAA.
Methods: PubMed, Embase, Web of Science, and Cochrane Library databases were systematically reviewed according to the Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) guidelines for PSI TAA. The quality of the included studies was evaluated according to Methodological Index for Non-Randomized Studies (MINORS).
Result: Nine articles were ultimately included in the systematic review. The implant position and function outcome of TAA was similar between PSI and SI. Prediction accuracy of implant size remained great difference. PSI can shorten the operative time and fluoroscopy time. The quality of current studies on PSI TAA is insufficient to produce high-level evidence.
Conclusion: PSI can get similar implant position and clinical outcome in TAA compared to SI, but current evidence is not strong enough to evaluate PSI TAA.
Keywords: Implant position; Implant size; PSI; Systematic review; TAA.
© 2021. SICOT aisbl.
References
-
- Onggo J, Nambiar M, Phan K, Hickey B, Galvin M, Bedi H (2020) Outcome after total ankle arthroplasty with a minimum of five years follow-up: A systematic review and meta-analysis. Foot ankle surgery 26:556–563. https://doi.org/10.1016/j.fas.2019.07.006 - DOI - PubMed
-
- Fanelli D, Mercurio M, Castioni D, Sanzo V, Gasparini G, Galasso O (2021) End-stage ankle osteoarthritis: arthroplasty offers better quality of life than arthrodesis with similar complication and re-operation rates-an updated meta-analysis of comparative studies. International orthopaedics. https://doi.org/10.1007/s00264-021-05053-x
-
- Fischer S, Klug A, Faul P, Hoffmann R, Manegold S, Gramlich Y (2021) Superiority of upper ankle arthrodesis over total ankle replacement in the treatment of end-stage posttraumatic ankle arthrosis. Archives of orthopaedic and trauma surgery. https://doi.org/10.1007/s00402-020-03714-x
-
- Tochigi Y, Rudert M, Brown T, McIff T, Saltzman C (2005) The effect of accuracy of implantation on range of movement of the Scandinavian Total Ankle Replacement. J bone joint surg Br 87:736–740. https://doi.org/10.1302/0301-620x.87b5.14872 - DOI - PubMed
-
- Barg A, Elsner A, Anderson A, Hintermann B (2011) The effect of three-component total ankle replacement malalignment on clinical outcome: pain relief and functional outcome in 317 consecutive patients. J bone joint surg Am 93:1969–1978. https://doi.org/10.2106/jbjs.J.01415 - DOI - PubMed