Infection prevention in endoscopy practice: comparative evaluation of re-usable vs single-use endoscopic valves

Affiliations

Infection prevention in endoscopy practice: comparative evaluation of re-usable vs single-use endoscopic valves

L Pasquale et al. Infect Prev Pract. .

Abstract

Re-usable air/water and suction valves used in endoscopes often demonstrate risk of infection. To the authors' knowledge, the safety and efficacy of re-usable and single-use valves have not been compared to date. As such, a laboratory investigation was undertaken to compare the safety and efficacy of re-usable and single-use valves at 11 Italian endoscopy sites. Safety was evaluated by analysing the rinse liquid of reprocessed re-usable valves ready for use, and efficacy was assessed based on the completion of endoscopic procedures without valve malfunction. This study found significantly lower contamination of single-use valves compared with re-usable valves (0 vs 29.1%, respectively; P=0.007) and similar efficacy (97.6 vs 98.8%, respectively; P=ns). Microbiological analysis of the rinse liquid of reprocessed re-usable valves identified various surviving micro-organisms and highlighted their potential pathogenicity. Such data suggest that sterile single-use valves may be safer than re-usable valves, and have comparable performance.

Keywords: Efficacy; Endoscopy; Infection; Re-usable valves; Safety; Single-use valves.

PubMed Disclaimer

References

    1. Riebe O., Beilenhoff U., von Rheinbaben F., Werner S. HYGENDA 2013 hygiene for endoscope reprocessing: study on the reprocessing of flexible endoscopes and their valves in hospitals and medical offices. Hyg Med. 2015;40:88–96.
    1. Parente DM. Could biopsy port valves be a source for potential flexible endoscope contamination? Available at: https://braun-scandinavia.dk/images/Dokumentation/USE/Biopsiventiler/USE... [last accessed February 2021].
    1. Pearce P.J. American Society of Clinical Pathologists; 2011. A report on the widespread inadequate reprocessing of endoscope air/water and suction valves by healthcare facilities.
    1. Olympus. Instructions for EVIS EXERA II duodenovideoscope Olympus TJF Type Q180V. Olympus. Available at: https://www.olympus-europa.com/medical/rmt/media/en/Content/Content-MSD/... [last accessed February 2021].
    1. Pajkos A., Vickery K., Cossart Y. Is biofilm accumulation on endoscope tubing a contributor to the failure of cleaning and decontamination? J Hosp Infect. 2004;58:224–229. - PubMed