Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2022 Apr 19;35(4):doab056.
doi: 10.1093/dote/doab056.

Indocyanine green (ICG) fluorescence imaging for prevention of anastomotic leak in totally minimally invasive Ivor Lewis esophagectomy: a systematic review and meta-analysis

Affiliations
Meta-Analysis

Indocyanine green (ICG) fluorescence imaging for prevention of anastomotic leak in totally minimally invasive Ivor Lewis esophagectomy: a systematic review and meta-analysis

María A Casas et al. Dis Esophagus. .

Abstract

Background: Indocyanine green (ICG) fluorescence imaging is an emerging technology that might help decreasing anastomotic leakage (AL) rates. The aim of this study was to determine the usefulness of ICG fluorescence imaging for the prevention of AL after minimally invasive esophagectomy with intrathoracic anastomosis.

Methods: A systematic literature review of the MEDLINE and Cochrane databases was performed to identify all articles on totally minimally invasive Ivor Lewis esophagectomy. Studies were then divided into two groups based on the use or not of ICG for perfusion assessment. Primary outcome was anastomotic leak. Secondary outcomes included operative time, ICG-related adverse reactions, and mortality rate. A meta-analysis was conducted to estimate the overall weighted proportion and its 95% confidence interval (CI) for main outcomes.

Results: A total of 3,171 patients were included for analysis: 381 (12%) with intraoperative ICG fluorescence imaging and 2,790 (88%) without ICG. Mean patients' age and proportion of males were similar between groups. Mean operative time was also similar between both groups (ICG: 354.8 vs. No-ICG: 354.1 minutes, P = 0.52). Mean ICG dose was 12 mg (5-21 mg). No ICG-related adverse reactions were reported. AL rate was 9% (95% CI, 5-17%) and 9% (95% CI, 7-12%) in the ICG and No-ICG groups, respectively. The risk of AL was similar between groups (odds ratio 0.85, 95% CI 0.53-1.28, P = 0.45). Mortality was 3% (95% CI, 1-9%) in patients with ICG and 2% (95% CI, 2-3%) in those without ICG. Median length of hospital stay was also similar between groups (ICG: 13.6 vs. No-ICG: 11.2 days, P = 0.29).

Conclusion: The use of ICG fluorescence imaging for perfusion assessment does not seem to reduce AL rates in patients undergoing minimally invasive esophagectomy with intrathoracic anastomosis.

Keywords: Ivor Lewis esophagectomy; fluorescence imaging; indocyanine green; minimally invasive esophagectomy; transthoracic esophagectomy.

PubMed Disclaimer

Substances

LinkOut - more resources