Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Sep;49(9):2635-2645.
doi: 10.1007/s10439-021-02844-6. Epub 2021 Aug 11.

Angioplasty Induced Changes in Dialysis Vascular Access Compliance

Affiliations

Angioplasty Induced Changes in Dialysis Vascular Access Compliance

Yihao Zheng et al. Ann Biomed Eng. 2021 Sep.

Abstract

Dialysis vascular access remains vitally important to maintain life and functional capacity with end stage renal disease. Angioplasty is an integral part of maintaining dialysis access function and patency. To understand the effect of angioplasty balloon dilation on vascular wall mechanics, we conducted a clinical study to evaluate the elastic modulus of the anastomosis in five subjects with anastomosis stenoses, before and after six angioplasty procedures, using B-mode ultrasound DICOM data. A novel and open source vascular ultrasound high-resolution speckle tracking software tool was used. The median lumen diameter increased from 3.4 to 5.5 mm after angioplasty. Meanwhile, the median elastic modulus of the 18 measurements at the anastomosis increased by 52.2%, from 2.24 × 103 to 3.41 × 103 mmHg. The results support our hypothesis that the structural changes induced in the vessel wall by balloon dilation lead to reduced vascular compliance and a higher elastic modulus of the vessel wall.

Keywords: Angioplasty; Arteriovenous fistula; Elastic modulus; Speckle tracking; Ultrasound; Vascular compliance.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Abbott W. M., J. Megerman, J. E. Hasson, G. L'Italien, and D. F. Warnock. Effect of compliance mismatch on vascular graft patency. J. Vasc. Surg. 5:376–382, 1987. - PubMed - DOI - PMC
    1. Balzani D., S. Brinkhues, and G. Holzapfel. Comparative study of polyconvex strainenergy functions used for the modeling of damage hysteresis in overstretched arterial walls. In: Proceedings of the 7th EUROMECH Solid Mechanics Conference, 2009.
    1. Bank A. J., H. Wang, J. E. Holte, K. Mullen, R. Shammas, and S. H. Kubo. Contribution of collagen, elastin, and smooth muscle to in vivo human brachial artery wall stress and elastic modulus. Circulation 94:3263–3270, 1996. - PubMed - DOI - PMC
    1. Belmont B., D. W. Park, A. Shih, M. Leavitt, B. Plattner, P. K. Henke, and W. F. Weitzel. A pilot study to measure vascular compliance changes during fistula maturation using open-source software. J. Vasc. Access 20:41–45, 2019. - PubMed - DOI - PMC
    1. Belmont B., D. W. Park, W. F. Weitzel, and A. J. Shih. An open-source ultrasound software for diagnosis of fistula maturation. ASAIO J. 64:70, 2018.

LinkOut - more resources