Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Nov;47(11):3159-3169.
doi: 10.1016/j.ultrasmedbio.2021.07.008. Epub 2021 Aug 12.

Operator Evaluation of Ultrasound Fusion Imaging Usefulness in the Percutaneous Ablation of Hepatic Malignancies: A Prospective Study

Affiliations

Operator Evaluation of Ultrasound Fusion Imaging Usefulness in the Percutaneous Ablation of Hepatic Malignancies: A Prospective Study

Alessandro Beleù et al. Ultrasound Med Biol. 2021 Nov.

Abstract

The purpose of the work described here was to evaluate the use of ultrasound fusion imaging (US-FI) in percutaneous ablation of hepatic malignancies with respect to its global usefulness, improvement of conspicuity, confidence increment, needle route changes, and time savings. Thirty-four hepatic tumors (28 hepatocellular carcinomas, 6 metastases) were prospectively ablated in 16 consecutive patients (64 ± 11 y, 75% males), first simulating B-mode-only planning and then synchronizing computed tomography/magnetic resonance images with US and proceeding to needle insertion and tumor ablation under US-FI guidance. Surveys were administered to the operators to evaluate their perception of US-FI advantages. First treatment and local recurrence were also compared. US-FI was judged useful in 91% of cases and more useful when the tumor was not conspicuous in B-mode (p < 0.001), in particular for ablation of local recurrences (p = 0.021). Forty-one percent of tumors were undetectable at B-mode evaluation, and 93% of them were completely ablated under US-FI guidance. The confidence of the operator was highly increased by US-FI in 68% of cases. In 71% of cases, the radiologist saved time using US-FI, especially in treatment of local recurrences (p = 0.024). In conclusion, US-FI significantly increases the detection of target tumors, improves the confidence of the operator and is a time-saving method, especially in the treatment of local recurrences.

Keywords: Interventional radiology; Liver; Radiofrequency ablation; Ultrasound.

PubMed Disclaimer

LinkOut - more resources