. 2022 Feb;26(2):1637-1645.
doi: 10.1007/s00784-021-04136-8. Epub 2021 Aug 16.

Impact of collar laser microtexturing on peri-implant health and disease: a retrospective clinical study

Affiliations

Impact of collar laser microtexturing on peri-implant health and disease: a retrospective clinical study

Mahdi Kadkhodazadeh et al. Clin Oral Investig. 2022 Feb.

Abstract

Objectives: This retrospective study was aimed to compare the clinical and radiographic outcomes of implants with the same body design but different collar surface (laser-microtextured vs. not laser-microtextured) after functional loading.

Materials and methods: Forty-three patients (29 females, 14 males) with 139 implants (60 laser-microtextured and 79 without laser microtexturing) were included in this study. Patients were consecutively included, and the data were collected during their implant maintenance visit. Clinical and radiographic parameters including probing depth (PD), bleeding on probing (BoP), and marginal bone loss (MBL) were recorded. In addition, the implant success index (ISI) score was determined. Statistical analysis was performed using the Mann-Whitney U test, the Kruskal-Wallis rank test, or the Pearson χ2 test, along with binary logistic regression (p < 0.05 was considered to be statistically significant).

Results: The median post-loading follow-up was 24 months with 100% survival rate. There was no significant differences in terms of mean PD (3.01 mm vs. 2.63 mm), mean MBL (0.54 vs. 0.49 mm), BoP (56.7% vs. 53.2%), and ISI score between laser-microtextured collars and implants without laser microtexturing. Logistic regression revealed arch as a significant predictor of peri-implantitis (p = 0.02).

Conclusion: Within the limitations of this study, there was no statistically significant difference between the clinical and radiographic outcomes of implants with laser-microtextured and non-laser-microtextured collar designs. Clinical relevance Prospective studies with larger sample sizes and careful monitoring of implant placement protocols are needed for definite conclusions.

Keywords: Collar design; Implant success index; Marginal bone level; Peri-implantitis.

PubMed Disclaimer

References

    1. Kotsakis GA (2000) Olmedo DG (2021) Peri-implantitis is not periodontitis: scientific discoveries shed light on microbiome-biomaterial interactions that may determine disease phenotype. Periodontol 86(1):231–240. https://doi.org/10.1111/prd.12372 - DOI
    1. Suarez-Lopez Del Amo F, Lin GH, Monje A, Galindo-Moreno P, Wang HL (2016) Influence of soft tissue thickness on peri-implant marginal bone loss: a systematic review and meta-analysis. J Periodontol 87(6):690–699. https://doi.org/10.1902/jop.2016.150571 - PubMed - DOI
    1. de Brandao ML, Vettore MV, Vidigal Junior GM (2013) Peri-implant bone loss in cement- and screw-retained prostheses: systematic review and meta-analysis. J Clin Periodontol 40(3):287–295. https://doi.org/10.1111/jcpe.12041 - PubMed - DOI
    1. Koutouzis T (2000) (2019) Implant-abutment connection as contributing factor to peri-implant diseases. Periodontol 81(1):152–166. https://doi.org/10.1111/prd - DOI
    1. Bonfante EA, Jimbo R, Witek L, Tovar N, Neiva R, Torroni A et al (2000) (2019) Biomaterial and biomechanical considerations to prevent risks in implant therapy. Periodontol 81(1):139–151. https://doi.org/10.1111/prd.12288 - DOI

Substances

LinkOut - more resources