. 2022 Aug;36(4):1147-1153.
doi: 10.1007/s10877-021-00749-2. Epub 2021 Aug 18.

Evaluation of a novel mobile phone application for blood pressure monitoring: a proof of concept study

Affiliations

Evaluation of a novel mobile phone application for blood pressure monitoring: a proof of concept study

Olivier Desebbe et al. J Clin Monit Comput. 2022 Aug.

Abstract

To provide information about the clinical relevance of blood pressure (BP) measurement differences between a new smartphone application (OptiBP™) and the reference method (automated oscillometric technique) using a noninvasive brachial cuff in patients admitted to the emergency department. We simultaneously recorded three BP measurements using both the reference method and the novel OptiBP™ (test method), except when the inter-arm difference was > 10 mmHg BP. Each OptiBP™ measurement required 1-min and the subsequent reference method values were compared to the values obtained with OptiBP™ using a Bland-Altman analysis and error grid analysis. Among the 110 patients recruited, OptiBP™ BP values could be collected on 61 patients (55%) and were included in the statistical analysis. The mean of differences (95% limits of agreement) between the reference method and the test method were - 0.1(- 22.5 to 22.4 mmHg) for systolic arterial pressure (SAP), - 0.1(- 12.9 to 12.7 mmHg) for diastolic arterial pressure (DAP) and - 0.3(- 18.1 to 17.4 mmHg) for mean arterial pressure (MAP). The proportions of measurements in risk zones A-E were 86.9%, 13.1%, 0%, 0%, and 0% for MAP and 89.3%, 10.7%, 0%, 0%, and 0% for SAP. In this pilot study conducted in stable and awake patients admitted to the emergency department, the absolute agreement between the OptiBP™ and the reference method was moderate. However, when BP measurements were made immediately after an initial calibration, error grid analysis showed that 100% of measurement differences between the OptiBP™ and reference method were categorized as no- or low-risk treatment decisions for all patients.Trial Registration: ClinicalTrials.gov Identifier: NCT04121624.

Keywords: Arterial pressure; Hemodynamic; Hypertension; Hypotension; Smartphone.

PubMed Disclaimer

References

    1. Elliott WJ. Systemic hypertension. Curr Probl Cardiol. 2007;32:201–59. - DOI
    1. Williams B, Mancia G, Spiering W, et al. 2018 ESC/ESH Guidelines for the management of arterial hypertension: The task force for the management of arterial hypertension of the European Society of Cardiology and the European Society of Hypertension: The task force for the management of arterial hypertension of the European Society of Cardiology and the European Society of Hypertension. J Hypertens. 2018;36:1953–2041. - DOI
    1. Patel AA. Developing and evaluating mhealth solutions for chronic disease prevention in primary care. Circulation. 2019;139:392–4. - DOI
    1. Stojanova A, Koceski S, Koceska N. Continuous blood pressure monitoring as a basis for Ambient Assisted Living (AAL)—review of methodologies and devices. J Med Syst. 2019;43:24. - DOI
    1. Ghamri Y, Proença M, Hofmann G, et al. Automated pulse oximeter waveform analysis to track changes in blood pressure during anesthesia induction: A proof-of-concept study. Anesth Analg. 2020;130:1222–33. - DOI