Rapid visual detection of Aeromonas salmonicida by loop-mediated isothermal amplification with hydroxynaphthol blue dye
- PMID: 34411329
- DOI: 10.1111/jfd.13513
Rapid visual detection of Aeromonas salmonicida by loop-mediated isothermal amplification with hydroxynaphthol blue dye
Abstract
To make crucial prevention, reduce fish losses and minimize the economic damage of diseases on the fish farm owners, a rapid detection of fish pathogens is mandatory. In this study, a loop-mediated isothermal amplification assay combined with hydroxynaphthol blue dye (LAMP-HNB) was developed and used for the rapid detection of Aeromonas salmonicida that caused significant economic losses in fish farming. Firstly, a pair of outer and inner primers specific for conserved fragment of vapA gene in A. salmonicida were designed and synthesized. Secondly, by optimizing the reaction conditions including reaction temperature, time, Mg2+ concentration, dNTP concentration and primer ratio, a LAMP-HNB assay was successfully established for the detection of A. salmoncida. Thirdly, the assay showed good specificity with no false-positive and false-negative results, and good sensitivity with the detection limit of 3.077 × 10-6 ng/μl, which was 102 times more sensitive than the conventional PCR. Finally, the LAMP-HNB assay was validated by the fish samples inoculated with different concentrations of A. salmoncida. This is the first development of rapid visual detection of A. salmonicida based on LAMP-HNB assay, which has great application prospect and market for diagnostic testing, health certification and active surveillance programmers.
Keywords: Aeromonas salmonicida; hydroxynaphthol blue dye; loop-mediated isothermal amplification; vapA gene; visual detection.
© 2021 John Wiley & Sons Ltd.
References
REFERENCES
-
- Abu Al-Soud, W., & Rådström, P. (2000). Effects of amplification facilitators on diagnostic PCR in the presence of blood, feces, and meat. Journal of Clinical Microbiology, 38(12), 4463-4470. https://doi.org/10.1128/jcm.38.12.4463-4470.2000
-
- Aizawa, Y., Oishi, T., Tsukano, S., Taguchi, T., & Saitoh, A. (2014). Clinical utility of loop-mediated isothermal amplification for rapid diagnosis of Mycoplasma pneumoniae in children. Journal of Medical Microbiology, 63(Pt 2), 248-251. https://doi.org/10.1099/jmm.0.068288-0
-
- Al-Soud, W. A., Jönsson, L. J., & Râdström, P. (2000). Identification and characterization of immunoglobulin G in blood as a major inhibitor of diagnostic PCR. Journal of Clinical Microbiology, 38(1), 345-350. https://doi.org/10.1128/JCM.38.1.345-350.2000
-
- Anupama, K. P., Deeksha, K., Deeksha, A., Karunasagar, I., Karunasagar, I., & Maiti, B. (2019). Comparative performance of TCBS and TSA for the enumeration of trh+ Vibrio parahaemolyticus by direct colony hybridization. Journal of Microbiol Methods, 157, 37-42. https://doi.org/10.1016/j.mimet.2018.12.020
-
- Anupama, K. P., Nayak, A., Karunasagar, I., & Maiti, B. (2020). Rapid visual detection of Vibrio parahaemolyticus in seafood samples by loop-mediated isothermal amplification with hydroxynaphthol blue dye. World Journal of Microbiology & Biotechnology, 36(5), 76. https://doi.org/10.1007/s11274-020-02851-0
MeSH terms
Substances
Supplementary concepts
Grants and funding
- Key Research and Development Program in Shandong
- Breeding Plan of Shandong Provincial Qingchuang Research Team
- the Advanced Talents Foundation of QAU
- Natural Science Foundation of Shandong Province
- "First class fishery discipline" programme in Shandong Province, special top talent plan "One Thing One Decision (Yishi Yiyi)"