Helmet noninvasive ventilation compared to facemask noninvasive ventilation and high-flow nasal cannula in acute respiratory failure: a systematic review and meta-analysis
- PMID: 34413155
- DOI: 10.1183/13993003.01269-2021
Helmet noninvasive ventilation compared to facemask noninvasive ventilation and high-flow nasal cannula in acute respiratory failure: a systematic review and meta-analysis
Abstract
Background: Although small randomised controlled trials (RCTs) and observational studies have examined helmet noninvasive ventilation (NIV), uncertainty remains regarding its role. We conducted a systematic review and meta-analysis to examine the effect of helmet NIV compared to facemask NIV or high-flow nasal cannula (HFNC) in acute respiratory failure.
Methods: We searched multiple databases to identify RCTs and observational studies reporting on at least one of mortality, intubation, intensive care unit (ICU) length of stay, NIV duration, complications or comfort with NIV therapy. We assessed study risk of bias using the Cochrane Risk of Bias 2 tool for RCTs and the Ottawa-Newcastle Scale for observational studies, and rated certainty of pooled evidence using the GRADE (Grading of Recommendations, Assessment, Development and Evaluation) framework.
Results: We separately pooled data from 16 RCTs (n=949) and eight observational studies (n=396). Compared to facemask NIV, based on low certainty of evidence, helmet NIV may reduce mortality (relative risk 0.56, 95% CI 0.33-0.95) and intubation (relative risk 0.35, 95% CI 0.22-0.56) in both hypoxic and hypercapnic respiratory failure, but may have no effect on duration of NIV. There was an uncertain effect of helmet NIV on ICU length of stay and development of pressure sores. Data from observational studies were consistent with the foregoing findings but of lower certainty. Based on low and very low certainty data, helmet NIV may reduce intubation compared to HFNC, but its effect on mortality is uncertain.
Conclusions: Compared to facemask NIV, helmet NIV may reduce mortality and intubation; however, the effect of helmet NIV compared to HFNC remains uncertain.
Copyright ©The authors 2022. For reproduction rights and permissions contact permissions@ersnet.org.
Conflict of interest statement
Conflict of interest: D. Chaudhuri has nothing to disclose. Conflict of interest: R. Jinah has nothing to disclose. Conflict of interest: K.E.A. Burns has nothing to disclose. Conflict of interest: F. Angriman has nothing to disclose. Conflict of interest: B.L. Ferreyro is supported by a Vanier Canada Graduate Scholarship. Conflict of interest: L. Munshi has nothing to disclose. Conflict of interest: E. Goligher has nothing to disclose. Conflict of interest: D. Scales has nothing to disclose. Conflict of interest: D.J. Cook has nothing to disclose. Conflict of interest: T. Mauri received personal fees from Drager, Fisher & Paykel and BBraun, all outside of the submitted work. Conflict of interest: B. Rochwerg has nothing to disclose.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical