Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2022 Jan;207(1):152-160.
doi: 10.1097/JU.0000000000002146. Epub 2021 Aug 24.

Contrast-Enhanced Ultrasound and Shear Wave Elastography: Novel Methods for the Evaluation of Urethral Stricture Disease

Affiliations

Contrast-Enhanced Ultrasound and Shear Wave Elastography: Novel Methods for the Evaluation of Urethral Stricture Disease

Paul H Chung et al. J Urol. 2022 Jan.

Abstract

Purpose: Urologists will benefit from an imaging modality which can assess intra and extraluminal characteristics of urethral strictures. We conducted a prospective pilot study evaluating the utility of contrast-enhanced ultrasound and shear wave elastography for the evaluation of bulbar urethral stricture disease.

Materials and methods: Patients with a single, bulbar urethral stricture were prospectively recruited. Contrast-enhanced ultrasound and shear wave elastography were performed at the time of surgical repair and at 4 months' followup using an Aplio i800 scanner (Canon Medical Systems, Tustin, California) with an i8CX1 transducer. Sulfur hexafluoride lipid-type A microsphere ultrasound contrast (Lumason®, Bracco Imaging, Princeton, New Jersey) was injected retrograde through the urethra. Stiffness of the corpus spongiosum was measured at and adjacent to the stricture site. Stricture lengths based on retrograde urethrogram, grayscale ultrasound and contrast-enhanced ultrasound were correlated with measured intraoperative stricture length.

Results: Thirty men were enrolled. Contrast-enhanced ultrasound (R2=0.709) showed the best correlation with intraoperative measured stricture length compared to retrograde urethrogram (R2=0.016) or grayscale ultrasound (R2=0.471). Stiffness of the spongiosum was greater at the site of the stricture (32.6±5.4 vs 27.3±5.8 kPa, p=0.044) and in narrower caliber strictures (p=0.044) but did not differ by stricture length (p=0.182). At followup (4.3±1.1 months) contrast-enhanced ultrasound detected stricture recurrence with 80% sensitivity, 100% specificity, and 93% accuracy compared to cystoscopy.

Conclusions: This pilot study demonstrates the ability of contrast-enhanced ultrasound and shear wave elastography to become safe, accurate, and potentially efficacious modalities for assessing bulbar urethral strictures and spongiofibrosis.

Keywords: contrast media; elasticity imaging techniques; microbubbles; ultrasonography; urethral stricture.

PubMed Disclaimer

Comment in

Publication types

LinkOut - more resources