Optimal number of needle punctures in endoscopic ultrasound-guided fine-needle biopsy for gastric subepithelial lesions without rapid on-site evaluation
- PMID: 34463865
- DOI: 10.1007/s10396-021-01129-8
Optimal number of needle punctures in endoscopic ultrasound-guided fine-needle biopsy for gastric subepithelial lesions without rapid on-site evaluation
Abstract
Purpose: The utility of endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) for gastric subepithelial lesions (SELs) has been reported. In this study, we examined the optimal number of needle punctures during EUS-FNB for gastric SELs without rapid on-site evaluation (ROSE). The factors that allowed for a single needle puncture to arrive at the correct diagnosis were also analyzed.
Methods: We conducted a retrospective study of all patients who underwent EUS-FNB to evaluate gastric SELs between April 2015 and September 2020; 51 patients with 57 gastric SELs were enrolled. The optimal number of needle punctures was determined when additional needle passes did not increase diagnostic sensitivity by more than 10%. Factors allowing for only a single needle puncture to arrive at the correct diagnosis were identified by univariate and multivariate logistic regression analyses.
Results: EUS-FNB resulted in a definitive final diagnosis in 48 of 57 lesions (84%). Lesions in the gastric body (odds ratio [OR] 6.15, 95% confidence interval [CI] 1.75-21.6; P < 0.01) and lesions punctured using a 22G Franseen needle (OR 3.61, 95% CI 1.07-12.3; P = 0.04) were independent factors that allowed for only a single needle puncture to arrive at the correct diagnosis. The optimal number of needle punctures for lesions using a 22G Franseen needle in the gastric body and other lesions was two and three, respectively.
Conclusion: The optimal number of needle punctures in EUS-FNB for gastric SELs without ROSE was two or three, depending on the location and type of needle used.
Keywords: Endoscopic ultrasound-guided fine-needle aspiration; Endoscopic ultrasound-guided fine-needle biopsy; Number of needle punctures; Stomach; Subepithelial lesion.
© 2021. The Japan Society of Ultrasonics in Medicine.
References
-
- Vilmann P, Jacobsen GK, Henriksen FW, et al. Endoscopic ultrasonography with guided fine needle aspiration biopsy in pancreatic disease. Gastrointest Endosc. 1992;38:172–3. - DOI
-
- Kurita A, Kodama Y, Nakamoto Y, et al. Impact of EUS-FNA for preoperative para-aortic lymph node staging in patients with pancreatobiliary cancer. Gastrointest Endosc. 2016;84:467-75.e1. - DOI
-
- Gleeson FC, Rajan E, Levy MJ, et al. EUS-guided FNA of regional lymph nodes in patients with unresectable hilar cholangiocarcinoma. Gastrointest Endosc. 2008;67:438–43. - DOI
-
- Nishida T, Kawai N, Yamaguchi S, et al. Submucosal tumors: comprehensive guide for the diagnosis and therapy of gastrointestinal submucosal tumors. Dig Endosc. 2013;25:479–89. - DOI
-
- Mekky MA, Yamao K, Sawaki A, et al. Diagnostic utility of EUS-guided FNA in patients with gastric submucosal tumors. Gastrointest Endosc. 2010;71:913–9. - DOI