Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Case Reports
. 2022 Feb;50(2):172-175.
doi: 10.1002/jcu.23059. Epub 2021 Sep 4.

Percutaneous closure of a paravalvular prosthetic mitral leak complicated by need for acute hemodialysis

Affiliations
Case Reports

Percutaneous closure of a paravalvular prosthetic mitral leak complicated by need for acute hemodialysis

Fabiola Sozzi et al. J Clin Ultrasound. 2022 Feb.

Abstract

A case of a severe paravalvular mechanical mitral prosthesis leak (PVL) in a high-risk surgical patient, complicated with acute heart failure at presentation is described. Considering the high surgical risk and the specific echocardiographic features that would prevent the interventional cardiologist to have a direct access to the PVL with a traditional vascular plug or duct occluder, a percutaneous PVL closure with an Amplatzer-Amulet (Abbott, Abbott Park, Illinois, United States) LAA device (28 mm) was chosen for the contiguity of the PVL to the left atrial appendage (LAA). A new-onset hemolysis post-PVL closure and severe renal failure requiring hemodialysis occurred after the procedure, treated with surgical device removal and leak suture. To the best of our knowledge, this is the first case that describes the attempt to close a PVL, contiguous to the LAA, using the Amulet device. The attempt to close a PVL with these features with an Amplatzer-Amulet device, although promising, does not appear completely safe to reach the goal, as in our case. In our opinion, the most important reasons are that specific technical recommendations and broad experiences are lacking. Indeed, specific outcomes of this kind of approach are, to date, still unknown.

Keywords: Amulet-Amplatzer device; paravalvular leak; percutaneous closure; prosthetic mitral valve.

PubMed Disclaimer

References

REFERENCES

    1. Smith CR, Stamou SC, Merhi WM, Hooker RL. Repair of paravalvular prosthetic mitral valve leaks with septal occluder devices in severely high-risk patients: a word of caution. Interact Cardiovasc Thorac Surg. 2012;15(3):544-546.
    1. Genoni M, Franzen D, Vogt P, et al. Paravalvular leakage after mitral valve replacement: improved long-term survival with aggressive surgery? Eur J Cardiothorac Surg. 2000;17:14-19.
    1. Kliger C, Eiros R, Isasti G, et al. Review of surgical prosthetic paravalvular leaks: diagnosis and catheter-based closure. Eur Heart J. 2013 Mar;34(9):638-649.
    1. Nishimura RA, Otto CM, Bonow RO, et al. 2014 AHA/ACC guideline for the management of patients with valvular heart disease: a report of the ACC/AHA task force. Circulation. 2014;129:2440-2492.
    1. Panaich S, Raphael CE, Maor E, Rihal CS. Transcatheter management of paravalvular leaks. https://www.acc.org/latest-in-cardiology/articles/2017/02/02/08/25/trans....

Publication types

LinkOut - more resources