Risk of Stroke After Transcatheter Aortic Valve Implantation: Epidemiology, Mechanism, and Management
- PMID: 34491954
- DOI: 10.1097/MJT.0000000000001413
Risk of Stroke After Transcatheter Aortic Valve Implantation: Epidemiology, Mechanism, and Management
Abstract
Background: Transcatheter aortic valve implantation (TAVI) has become an established and increasingly used approach for management of severe symptomatic aortic stenosis, showing similar or even superior outcomes compared with standard surgical aortic valve replacement (SAVR). Stroke after TAVI is a relatively rare, but serious complication, associated with potential prolonged disability and increased mortality.
Areas of uncertainty: The overall incidence of 30-day stroke in TAVI patients is 3%-4%, but varies between different trials. Initial data suggested a higher risk of stroke after TAVI when compared with SAVR. The association between subclinical leaflet thrombosis and cerebral embolism, presented as stroke, transient ischemic accident, or silent cerebral ischemia is not entirely elucidated yet. Moreover, TAVI for severe bicuspid aortic stenosis is a relatively new issue, bicuspid anatomy being initially excluded from the pivotal clinical trials investigating TAVI procedure. Efficient stroke prevention strategies are under investigation.
Data sources: In the present manuscript, we used the available published data from the most relevant clinical trials, registries, and meta-analysis of patients from different risk categories who underwent TAVI or SAVR.
Therapeutic advances: Predictors of acute stroke are mainly procedure related. Technological development, improvements in bioprosthesis valve delivery catheters, and implantation technique may explain the decrease of stroke over the years since the beginning of TAVI procedures.
Conclusions: The overall evidences confirm similar or lower rate of stroke in TAVI versus SAVR. Risk predictors for acute stroke after TAVI are generally related to procedural factors, whereas late stroke is mainly associated with patient characteristics, with a variable impact on cognitive function. The optimal choice for the antithrombotic treatment in TAVI for stroke prevention is yet to be determined. Current data do not support routine use of cerebral embolic protection devices during TAVI.
Copyright © 2021 Wolters Kluwer Health, Inc. All rights reserved.
Conflict of interest statement
The authors have no conflicts of interest to declare.
Similar articles
-
Transcatheter Aortic Valve Implantation in Patients With Severe Aortic Valve Stenosis at Low Surgical Risk: A Health Technology Assessment.Ont Health Technol Assess Ser. 2020 Nov 2;20(14):1-148. eCollection 2020. Ont Health Technol Assess Ser. 2020. PMID: 33240455 Free PMC article.
-
Exploring the Difference in Post-procedural Stroke Rates Between Patients with Aortic Stenosis Who Undergo Transcatheter Aortic Valve Replacement Versus Surgical Aortic Valve Replacement.Cureus. 2018 Apr 17;10(4):e2494. doi: 10.7759/cureus.2494. Cureus. 2018. PMID: 29922535 Free PMC article. Review.
-
Risk of Ischemic Stroke in Transcatheter Aortic Valve Implantation Versus Surgical Aortic Valve Replacement in Patients With Prior Stroke.Am J Cardiol. 2021 Oct 15;157:79-84. doi: 10.1016/j.amjcard.2021.06.049. Epub 2021 Aug 6. Am J Cardiol. 2021. PMID: 34366113
-
Transcatheter Aortic Valve Implantation in Patients With Severe, Symptomatic Aortic Valve Stenosis at Intermediate Surgical Risk: A Health Technology Assessment.Ont Health Technol Assess Ser. 2020 Mar 6;20(2):1-121. eCollection 2020. Ont Health Technol Assess Ser. 2020. PMID: 32194880 Free PMC article.
-
Transcatheter aortic valve implantation versus surgical aortic valve replacement for severe aortic stenosis: results from an intermediate risk propensity-matched population of the Italian OBSERVANT study.Int J Cardiol. 2013 Sep 1;167(5):1945-52. doi: 10.1016/j.ijcard.2012.05.028. Epub 2012 May 26. Int J Cardiol. 2013. PMID: 22633667 Clinical Trial.
Cited by
-
Management of Acute Ischemic Stroke Following Transcatheter Aortic Valve Implantation: A Systematic Review and Multidisciplinary Treatment Recommendations.J Clin Med. 2024 Dec 6;13(23):7437. doi: 10.3390/jcm13237437. J Clin Med. 2024. PMID: 39685895 Free PMC article. Review.
-
Outcomes of Cerebral Embolic Protection for Bicuspid Aortic Valve Stenosis Undergoing Transcatheter Aortic Valve Replacement.J Am Heart Assoc. 2023 Jun 20;12(12):e028890. doi: 10.1161/JAHA.122.028890. Epub 2023 Jun 10. J Am Heart Assoc. 2023. PMID: 37301750 Free PMC article.
-
Single arm meta-analysis of the J-Valve system for aortic regurgitation in Chinese populations.Front Cardiovasc Med. 2025 May 21;12:1436789. doi: 10.3389/fcvm.2025.1436789. eCollection 2025. Front Cardiovasc Med. 2025. PMID: 40469077 Free PMC article.
-
A Two-Step Risk Score for Prediction of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Implantation.J Am Heart Assoc. 2025 May 20;14(10):e039036. doi: 10.1161/JAHA.124.039036. Epub 2025 May 15. J Am Heart Assoc. 2025. PMID: 40371590 Free PMC article.
-
Fighting Cardiac Thromboembolism during Transcatheter Procedures: An Update on the Use of Cerebral Protection Devices in Cath Labs and EP Labs.Life (Basel). 2023 Aug 28;13(9):1819. doi: 10.3390/life13091819. Life (Basel). 2023. PMID: 37763223 Free PMC article. Review.
References
-
- Baumgartner H, Falk V, Bax JJ, et al. 2017 ESC/EACTS guidelines for the management of valvular heart disease. Eur Heart J. 2017;38:2739–2791.
-
- Huded CP, Tuzcu EM, Krishnaswamy A, et al. Association between transcatheter aortic valve replacement and early postprocedural stroke. JAMA. 2019;321:2306–2315.
-
- Armijo G, Nombela-Franco L, Tirado-Conte G. Cerebrovascular events after transcatheter aortic valve implantation. Front Cardiovasc Med. 2018;5:104.
-
- Auffret V, Regueiro A, Del Trigo M, et al. Predictors of early cerebrovascular events in patients with aortic stenosis undergoing transcatheter aortic valve replacement. J Am Coll Cardiol. 2016;68:673–684.
-
- Leon MB, Smith CR, Mack M, et al.; for the PARTNER Trial Investigators. Transcatheter aortic-valve implantation for aortic stenosis for patients who cannot undergo surgery. N Engl J Med. 2010;363:1597–1607.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials