How much safety is actually 'safe'? Commentary on 'Safety of the Apollo Onyx delivery microcatheter for embolization of brain arteriovenous malformations: results from a prospective post-market study' by Meyers et al
- PMID: 34493576
- PMCID: PMC8458087
- DOI: 10.1136/neurintsurg-2021-018052
How much safety is actually 'safe'? Commentary on 'Safety of the Apollo Onyx delivery microcatheter for embolization of brain arteriovenous malformations: results from a prospective post-market study' by Meyers et al
Keywords: arteriovenous malformation; catheter.
Conflict of interest statement
Competing interests: None declared.
Figures
Comment on
-
Safety of the APOLLO Onyx delivery microcatheter for embolization of brain arteriovenous malformations: results from a prospective post-market study.J Neurointerv Surg. 2021 Oct;13(10):935-941. doi: 10.1136/neurintsurg-2020-016830. Epub 2021 Feb 1. J Neurointerv Surg. 2021. PMID: 33526480
Similar articles
-
Safety of the APOLLO Onyx delivery microcatheter for embolization of brain arteriovenous malformations: results from a prospective post-market study.J Neurointerv Surg. 2021 Oct;13(10):935-941. doi: 10.1136/neurintsurg-2020-016830. Epub 2021 Feb 1. J Neurointerv Surg. 2021. PMID: 33526480
-
Onyx embolization with the Apollo detachable tip microcatheter: A single-center experience.Interv Neuroradiol. 2018 Jun;24(3):339-344. doi: 10.1177/1591019918758494. Epub 2018 Feb 26. Interv Neuroradiol. 2018. PMID: 29482458 Free PMC article.
-
Over-the-catheter retrieval of a retained microcatheter following Onyx embolization: a technical report.J Neurointerv Surg. 2012 Jul;4(4):e13. doi: 10.1136/neurintsurg-2011-010040. Epub 2011 Jun 16. J Neurointerv Surg. 2012. PMID: 21990504
-
Asystole During Onyx Embolization of a Pediatric Arteriovenous Malformation: A Severe Case of the Trigeminocardiac Reflex.World Neurosurg. 2017 Feb;98:884.e1-884.e5. doi: 10.1016/j.wneu.2016.07.025. Epub 2016 Jul 17. World Neurosurg. 2017. PMID: 27436213 Review.
-
Pulmonary arteriovenous malformation embolization: how we do it.Tech Vasc Interv Radiol. 2013 Mar;16(1):39-44. doi: 10.1053/j.tvir.2013.01.005. Tech Vasc Interv Radiol. 2013. PMID: 23499130 Review.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical