Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Aug;117(2):404-406.
doi: 10.36660/abc.20201097.

Patient in Cardiorespiratory Arrest - Is it Possible to Perform Transcatheter Aortic Valve Implantation (TAVI) in this Scenario?

[Article in English, Portuguese]
Affiliations

Patient in Cardiorespiratory Arrest - Is it Possible to Perform Transcatheter Aortic Valve Implantation (TAVI) in this Scenario?

[Article in English, Portuguese]
Alexandre de Matos Soeiro et al. Arq Bras Cardiol. 2021 Aug.
No abstract available

PubMed Disclaimer

Conflict of interest statement

Potencial conflito de interesse

Não há conflito com o presente artigo

Figures

Figura 1
Figura 1. Ecocardiograma transtorácico em janela apical pré-TAVI mostrando valva aórtica calcificada com área valvar de 0,6 cm2 e gradiente ventrículo esquerdo-aorta máximo de 66 mmHg e médio de 35 mmHg.
Figura 2
Figura 2. Realização de TAVI com prótese Edward SAPIEN 3 no 26 somente com visualização da escopia durante manobras de RCP. A) Posicionamento dos cateteres. B) Alinhamento da prótese no anel valvar aórtico. C) Prótese colocada em posição aórtica.
Figura 3
Figura 3. Ecocardiograma transtorácico após TAVI mostrando fração de ejeção de ventrículo esquerdo de 33%, prótese em posição aórtica com gradiente ventrículo esquerdo-aorta máximo de 35 mmHg e médio de 17 mmHg, com insuficiência aórtica periprótese de discreta a moderada.
Figure 1
Figure 1. Transthoracic echocardiogram in pre-TAVI apical window showing a calcified aortic valve, with valvular area of 0.6 cm2 and maximum left ventricle-aorta gradient of 66 mmHg and mean gradient of 35 mmHg.
Figure 2
Figure 2. TAVI was performed with an Edwards SAPIEN 3 prosthesis n. 26, with scope visualization only, during CPR maneuvers. A) Positioning of catheters; B) Alignment of the prosthesis in the aortic valve annulus; C) Prosthesis shown in the aortic position.
Figure 3
Figure 3. Transthoracic echocardiogram after TAVI, showing a left ventricular ejection fraction of 33%, prosthesis in the aortic position with a maximum left ventricle-aortic gradient of 35 mmHg and a mean gradient of 17 mmHg, with mild to moderate peri-prosthesis aortic insufficiency.

References

    1. 1. Alkhalil A, Hajjar R, Ibrahim H, Ruiz CE. Mechanical circulatory support in transcatheter aortic valve implantation in the United States (from the National Inpatient Sample). Am J Cardiol. 2019;124(10):1615-20. doi: 10.1016/j.amjcard.2019.08.013. - PubMed
    1. 2. Satler LF, Pichard AD. The use of automated chest compression for arrest during TAVI. Catheter Cardiovasc Interv. 2013;82(5):849-50. doi: 10.1002/ccd.24968. - PubMed
    1. 3. Kim EK, Choi SH, Song PS, Park SJ. Valve prosthesis distortion after cardiac compression in a patient who underwent transcatheter aortic valve implantation (TAVI). Catheter Cardiovasc Interv. 2014;83(3):165-7. doi: 10.1002/ccd.24412. - PubMed
    1. 4. Fernandes P, Cleland A, Bainbridge D, Jones PM, Chu MW, Kiaii B. Development of our TAVI protocol for emergency initiation of cardiopulmonary bypass. Perfusion. 2015;30(1):34-9. doi: 10.1177/0267659114547754. - PubMed

MeSH terms